Detailed Information

Cited 0 time in webofscience Cited 1 time in scopus
Metadata Downloads

Relationship between Cornea and Lid Margin Position on the Appearance of Strabismus

Authors
Wang, Dong HyunChang, Jee Ho
Issue Date
Jul-2015
Publisher
Lippincott Williams & Wilkins Ltd.
Keywords
strabismus; appearance; threshold; cornea; lid margin
Citation
Optometry and Vision Science, v.92, no.7, pp 815 - 822
Pages
8
Journal Title
Optometry and Vision Science
Volume
92
Number
7
Start Page
815
End Page
822
URI
https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/10511
DOI
10.1097/OPX.0000000000000619
ISSN
1040-5488
1538-9235
Abstract
Purpose Previous strabismus appearance studies using images from real face photographs could not preclude the effect of other facial landmarks, such as position and contour of brow, nose, and facial outline, from pure effect of ocular deviation itself. With conceptualized drawings of eyes, we simulated strabismus deviation and collected the responses of observers. Methods The experiments consisted of three sessions: (1) one-eye, (2) two-eye cornea, and (3) two-eyelid deviation simulations. On a monitor, eight different ocular deviations in increments of 6 prism diopters of horizontal or vertical deviations were simulated. Nine ophthalmology residents were asked to choose between esotropia and exotropia for horizontal simulations and hypotropia or hypertropia for vertical simulations. Psychometric function fitting was performed. Detection sensitivity, point of subjective equality, and 95% thresholds were calculated. Results Between cornea and lid deviation simulations, there was no difference in 95% thresholds, points of subjective equality, and sensitivity (all p values > 0.10), reflecting that the relative location of cornea and lid was the determinant factor in recognizing ocular deviation. The sensitivities of vertical deviation simulations were higher than that of horizontal in two-eye cornea and lid comparisons (p values < 0.04) but not in one-eye (p value = 0.37). Conclusions Our results suggest that the appearance of strabismus depends not on the absolute ocular alignment but rather on the reciprocal relationship of cornea and lid margin. Vertical misalignment was more apparent than horizontal misalignment.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Ophthalmology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher CHANG, JEE HO photo

CHANG, JEE HO
College of Medicine (Department of Ophthalmology)
Read more

Altmetrics

Total Views & Downloads

BROWSE