Detailed Information

Cited 0 time in webofscience Cited 3 time in scopus
Metadata Downloads

Heart monitoring using left ventricle impedance and ventricular electrocardiography in left ventricular assist device patients

Authors
Her, KeunAhn, Chi BumPark, Sung MinChoi, Seong Wook
Issue Date
21-Mar-2015
Publisher
BioMed Central
Keywords
흉부외과
Citation
BioMedical Engineering Online, v.14
Journal Title
BioMedical Engineering Online
Volume
14
URI
https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/10784
DOI
10.1186/s12938-015-0019-3
ISSN
1475-925X
Abstract
Background: Patients who develop critical arrhythmia during left ventricular assist device (LVAD) perfusion have a low survival rate. For diagnosis of unexpected heart abnormalities, new heart-monitoring methods are required for patients supported by LVAD perfusion. Ventricular electrocardiography using electrodes implanted in the ventricle to detect heart contractions is unsuitable if the heart is abnormal. Left ventricular impedance (LVI) is useful for monitoring heart movement but does not show abnormal action potential in the heart muscle. Objectives: To detect detailed abnormal heart conditions, we obtained ventricular electrocardiograms (v-ECGs) and LVI simultaneously in porcine models connected to LVADs. Methods: In the porcine models, electrodes were set on the heart apex and ascending aorta for real-time measurements of v-ECGs and LVI. As the carrier current frequency of the LVI was adjusted to 30 kHz, it was easily derived from the original v-ECG signal by using a high-pass filter (cutoff: 10 kHz). In addition, v-ECGs with a frequency band of 0.1 - 120 Hz were easily derived using a low-pass filter. Simultaneous v-ECG and LVI data were compared to detect heart volume changes during the Q-T period when the heart contracted. A new real-time algorithm for comparison of v-ECGs and LVI determined whether the porcine heartbeats were normal or abnormal. Several abnormal heartbeats were detected using the LVADs operating in asynchronous mode, most of which were premature ventricle contractions (PVCs). To evaluate the accuracy of the new method, the results obtained were compared to normal ECG data and cardiac output measured simultaneously using commercial devices. Results: The new method provided more accurate detection of abnormal heart movements. This method can be used for various heart diseases, even those in which the cardiac output is heavily affected by LVAD operation.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Cardiovascular Surgery > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE