Detailed Information

Cited 0 time in webofscience Cited 22 time in scopus
Metadata Downloads

Diagnostic accuracy of plasma free metanephrines in a seated position compared with 24-hour urinary metanephrines in the investigation of pheochromocytoma

Authors
Kim, Hye JeongLee, Ji InCho, Yoon YoungLee, Soo YounKim, Jung HanJung, Byong ChangKim, Sun WookChung, Jae HoonMin, Yong-KiLee, Myung-ShikLee, Moon-KyuKim, Jae Hyeon
Issue Date
20-Mar-2015
Publisher
Japan Endocrine Sociey/Nihon Naibunpi Gakkai
Keywords
Pheochromocytoma; Metanephrine
Citation
Endocrine Journal, v.62, no.3, pp 243 - 250
Pages
8
Journal Title
Endocrine Journal
Volume
62
Number
3
Start Page
243
End Page
250
URI
https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/10785
DOI
10.1507/endocrj.EJ14-0384
ISSN
0918-8959
1348-4540
Abstract
The aim of this study was to determine the diagnostic efficacy of free metanephrines in plasma samples drawn in the seated position compared with 24-h urinary metanephrines in detecting pheochromocytomas in Asian patients. This prospective study was conducted at Samsung Medical Center between May 2010 and July 2011. The study contained 245 subjects, including 28 patients with histologically-proven pheochromocytoma, 44 with histologically-proven non-pheochromocytoma, 112 controls suspected of having tumors but with negative investigations during two or more years of follow-up, and 45 healthy normotensive volunteers. Plasma-free metanephrines were measured by LC-MS/MS. The cut-off values with optimal sensitivity and specificity for plasma metanephrine and plasma normetanephrine were 0.33 nmol/L and 0.61 nmol/L, respectively. Both the plasma metanephrines measurement and urinary metanephrines measurement had a sensitivity of 96.4% (p = 1.00). However, the urinary metanephrines measurement was significantly more specific than the plasma metanephrines measurement (94.2% vs. 75.6%; p < 0.001). When we applied cut-off values based on BMI, specificity improved from 75.6% to 87.2%, with a comparable gain in sensitivity. From a diagnostic perspective, measurement of free metanephrines in plasma drawn in the seated position is highly sensitive but insufficiently specific when compared with measurement of 24-h urinary fractionated metanephrines. The specificity may be improved by applying cut-off values based on BMI. We suggest that free metanephrines in plasma drawn from seated position can also be used as an initial screening test to ensure that pheochromocytomas are not missed in Asian patients.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Internal Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, HYE JEONG photo

Kim, HYE JEONG
College of Medicine (Department of Internal Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE