Pretransplant Diagnosis of Hepatocellular Carcinoma by Gadoxetic Acid-Enhanced and Diffusion-Weighted Magnetic Resonance Imaging
- Authors
- Hwang, Jiyoung; Kim, Young Kon; Kim, Jong Man; Lee, Won Jae; Choi, Dongil; Hong, Seong Sook
- Issue Date
- Dec-2014
- Publisher
- John Wiley & Sons Inc.
- Keywords
- Pretransplant diagnosis of hepatocellular carcinoma by gadoxetic acid-enhanced and diffusion-weighted magnetic resonance imaging.
- Citation
- Liver Transplantation, v.20, no.12, pp 1436 - 1446
- Pages
- 11
- Journal Title
- Liver Transplantation
- Volume
- 20
- Number
- 12
- Start Page
- 1436
- End Page
- 1446
- URI
- https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/11675
- DOI
- 10.1002/lt.23974
- ISSN
- 1527-6465
1527-6473
- Abstract
- We sought to evaluate the diagnostic performance of gadoxetic acid-enhanced magnetic resonance imaging (MRI) with and without additional diffusion-weighted imaging (DWI) in the detection of hepatocellular carcinoma (HCC) in pretransplant patients. We included 63 liver transplant patients (54 men and 9 women; mean age=52 years) who had undergone gadoxetic acid-enhanced MRI with DWI at 3.0 T within 90 days before transplantation. Two image sets were reviewed for HCC in 2 separate sessions by 2 independent observers: the gadoxetic acid set and the combined set (gadoxetic acid plus DWI). The sensitivity, specificity, positive predictive value, and negative predictive value were calculated for each image set. In all, 113 HCCs (size range=0.5-7.8 cm, mean=2.0 +/- 1.3 cm) were identified in the 52 liver explants. The per-lesion sensitivity of the combined set (78.8% for both observers) was higher than the sensitivity of the gadoxetic acid set [71.7% (P=0.02) and 72.6% (P=0.03) for the 2 observers], with the highest trend for Child-Pugh class A (94.4% and 97.2% for gadoxetic acid and 97.2% for combined), which was followed by class B (73.2% for gadoxetic acid and 82.9% for combined) and then class C (47.2% for gadoxetic acid and 55.6% for combined, P=0.01). The per-patient negative predictive value of the combined set was higher than that of the gadoxetic acid set for both observers (P=0.046). There was no difference in specificity between the 2 image sets (P>0.05). The addition of DWI to gadoxetic acid-enhanced MRI resulted in significantly higher sensitivity to detect HCC. However, the sensitivity decreased with increasing cirrhosis severity for both imaging types. Liver Transpl 20:1436-1446, 2014. (c) 2014 AASLD.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - College of Medicine > Department of Radiology > 1. Journal Articles
![qrcode](https://api.qrserver.com/v1/create-qr-code/?size=55x55&data=https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/11675)
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.