Detailed Information

Cited 0 time in webofscience Cited 5 time in scopus
Metadata Downloads

MR imaging of articular cartilage at 1.5T and 3.0T: comparison of IDEAL 2D FSE and 3D SPGR with fat-saturated 2D FSE and 3D SPGR in a porcine model

Authors
Cha, Jang GyuYoo, Jae HoRhee, Sun JungHwang, Seung SikHan, Jong Kyu
Issue Date
May-2014
Publisher
Taylor & Francis
Keywords
cartilage; Knee joint; MR imaging; MR sequence; animal model
Citation
Acta Radiologica, v.55, no.4, pp 462 - 469
Pages
8
Journal Title
Acta Radiologica
Volume
55
Number
4
Start Page
462
End Page
469
URI
https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/12239
DOI
10.1177/0284185113497711
ISSN
0284-1851
1600-0455
Abstract
Background IDEAL technique is a robust fat-water separation method which is potentially useful in cartilage imaging with significant improvement in the cartilage signal-to-noise ratio (SNR). Purpose To identify whether iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) improved diagnostic performance for IDEAL 2D fast spin echo (FSE) and 3D spoiled gradient-recalled echo (SPGR) versus fat-saturated (FS) protocols at 1.5 and 3.0 T in the evaluation of patella-femoral cartilage lesions. Material and Methods Forty-six artificial cartilage lesions were created in femoro-patellar articular cartilages of 11 porcine knees. All knees underwent MR examination at 1.5 and 3.0 T with MR protocol consisting of sagittal FS 2D FSE and 3D SPGR and IDEAL 2D FSE and IDEAL 3D SPGR, respectively. Qualitative assessment was performed to compare the diagnostic performance between 1.5- and 3.0-T protocols and between IDEAL and FS protocols. Results IDEAL 3D SPGR had a significantly higher accuracy for detecting partial thickness cartilage lesions (P < 0.01) than FS SPGR protocols, whereas there was no significant difference in diagnostic performance between IDEAL and FS 2D FSE except for one cartilage lesion. For all imaging sequences, no significant difference was observed in the diagnostic performance between 1.5- and 3.0-T imaging protocols (P = 0.42-0.91). Conclusion Compared with conventional FS SPGR imaging, IDEAL 3D SPGR provided a better diagnostic performance for evaluation of porcine knee articular cartilage lesions in the knee joints at 1.5 and 3.0 T. IDEAL 3D SPGR may therefore be useful for detecting partial-thickness cartilage lesions in patients with degenerative osteoarthritis.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Radiology > 1. Journal Articles
College of Medicine > Department of Radiology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Han, Jong Kyu photo

Han, Jong Kyu
College of Medicine (Department of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE