Detailed Information

Cited 0 time in webofscience Cited 8 time in scopus
Metadata Downloads

Comparison of 2 cuff inflation methods of laryngeal mask airway Classic for safe use without cuff manometer in adults

Authors
Kim, Min-SooLee, Jeong-RimShin, Yang-SikChung, Ji-WonLee, Kyu-HoAhn, Ki Ryang
Issue Date
Mar-2014
Publisher
W. B. Saunders Co., Ltd.
Keywords
Comparison of 2 cuff inflation methods of laryngeal mask airway Classic for safe usewithout cuff manometer in adults
Citation
American Journal of Emergency Medicine, v.32, no.3, pp 237 - 242
Pages
6
Journal Title
American Journal of Emergency Medicine
Volume
32
Number
3
Start Page
237
End Page
242
URI
https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/12385
DOI
10.1016/j.ajem.2013.11.029
ISSN
0735-6757
1532-8171
Abstract
Purpose: This single-center, prospective, randomized, double-blind, 2-arm, parallel group comparison trial was performed to establish whether the adult-sized laryngeal mask airway (LMA) Classic (The Laryngeal Mask Company Ltd, Henley-on-Thames, UK) could be used safely without any consideration of cuff hyperinflation when a cuff of the LMA Classic was inflated using half the maximum inflation volume or the resting volume before insertion of device. Basic procedures: Eighty patients aged 20 to 70 years scheduled for general anesthesia using the LMA Classic were included. Before insertion, the cuff was partially filled with half the maximum inflation volume in the half volume group or the resting volume created by opening the pilot balloon valve to equalize with atmospheric pressure in the resting volume group. Several parameters regarding insertion, intracuff pressure, airway leak pressure, and leakage volume/fraction were collected after LMA insertion. Major findings: The LMA Classic with a partially inflated cuff was successfully inserted in all enrolled patients. Both groups had the same success rate of 95% at the first insertion attempt. The half volume group had a lower mean intracuff pressure compared with the resting volume group (54.5 +/- 16.1 cm H2O vs 61.8 +/- 16.1 cm H2O; P = .047). There was no difference in airway leak pressure or leakage volume/fraction between the 2 groups under mechanical ventilation. Conclusions: The partially inflated cuff method using half the maximum recommended inflation volume or the resting volume is feasible with the adult-sized LMA Classic, resulting in a high success rate of insertion and adequate range of intracuff pressures. (C) 2014 Elsevier Inc. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Anesthesiology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.