A Case of Sheathless Transradial Coronary Intervention for Complex Coronary Lesions with a Standard Guiding Catheter

Authors
Choi, JaehukSuh, JonSeo, Hye-SunCho, Yoon HaengLee, Nae Hee
Issue Date
May-2013
Publisher
대한심장학회
Keywords
Coronary artery disease; Radial artery
Citation
Korean Circulation Journal, v.43, no.5, pp 347 - 350
Pages
4
Journal Title
Korean Circulation Journal
Volume
43
Number
5
Start Page
347
End Page
350
URI
https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/13737
DOI
10.4070/kcj.2013.43.5.347
ISSN
1738-5520
1738-5555
Abstract
One of the major limitations of transradial coronary intervention is the inability to use large guiding system, which leads to the development of dedicated sheathless guide catheter system. However, these devices are not available in the Republic of Korea. We present a case in which conventional guiding catheter was used for sheathless transradial coronary intervention in the treatment of complex coronary anatomy.