A Comparative Quantitative Analysis of IDEAL (Iterative Decomposition of Water and Fat with Echo Asymmetry and Least Squares Estimation) and CHESS (Chemical Shift Selection Suppression) Technique in 3.0T Musculoskeletal MRI
- Authors
- Kim, Myoung-Hoon; Cho, Jae-Hwan; Shin, Seong-Gyu; Dong, Kyung-Rae; Chung, Woon-Kwan; Park, Tae-Hyun; Ahn, Jae-Ouk; Park, Cheol-Soo; Jang, Hyon-Chol; Kim, Yoon-Shin
- Issue Date
- Jun-2012
- Publisher
- 한국자기학회
- Keywords
- CHESS; IDEAL; susceptibility artifacts; homogeneous fat suppression
- Citation
- Journal of Magnetics, v.17, no.2, pp 145 - 152
- Pages
- 8
- Journal Title
- Journal of Magnetics
- Volume
- 17
- Number
- 2
- Start Page
- 145
- End Page
- 152
- URI
- https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/15121
- DOI
- 10.4283/JMAG.2012.17.2.145
- ISSN
- 1226-1750
2233-6656
- Abstract
- Patients who underwent hip arthroplasty using the conventional fat suppression technique (CHESS) and a new technique (IDEAL) were compared quantitatively to assess the effectiveness and usefulness of the IDEAL technique. In 20 patients who underwent hip arthroplasty from March 2009 to December 2010, fat suppression T2 and T1 weighted images were obtained on a 3.0T MR scanner using the CHESS and IDEAL techniques. The level of distortion in the area of interest, the level of the development of susceptibility artifacts, and homogeneous fat suppression were analyzed from the acquired images. Quantitative analysis revealed the IDEAL technique to produce a lower level of image distortion caused by the development of susceptibility artifacts due to metal on the acquired images compared to the CHESS technique. Qualitative analysis of the anterior area revealed the IDEAL technique to generate fewer susceptibility artifacts than the CHESS technique but with homogeneous fat suppression. In the middle area, the IDEAL technique generated fewer susceptibility artifacts than the CHESS technique but with homogeneous fat suppression. In the posterior area, the IDEAL technique generated fewer susceptibility artifacts than the CHESS technique. Fat suppression was not statistically different, and the two techniques achieved homogeneous fat suppression. In conclusion, the IDEAL technique generated fewer susceptibility artifacts caused by metals and less image distortion than the CHESS technique. In addition, homogeneous fat suppression was feasible. In conclusion, the IDEAL technique generates high quality images, and can provide good information for diagnosis.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - College of Medical Sciences > Department of Medical IT Engineering > 1. Journal Articles
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.