Detailed Information

Cited 0 time in webofscience Cited 1 time in scopus
Metadata Downloads

Quantitative Analysis of Tomotherapy, Linear-accelerator-based 3D Conformal Radiation Therapy, Intensity-modulated Radiation Therapy, and 4D Conformal Radiation Therapy

Authors
Cho, Jae-HwanLee, Hae-KagDong, Kyung-RaeChung, Woon-KwanLee, Jong-WoongPark, Hoon-Hee
Issue Date
Apr-2012
Publisher
한국물리학회
Keywords
3D CRT; IMRT; Tomotherapy; Gating-based 4D-CT treatment planning; DVH; GTV; PTV
Citation
Journal of the Korean Physical Society, v.60, no.7, pp 1167 - 1176
Pages
10
Journal Title
Journal of the Korean Physical Society
Volume
60
Number
7
Start Page
1167
End Page
1176
URI
https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/15270
DOI
10.3938/jkps.60.1167
ISSN
0374-4884
1976-8524
Abstract
This study quantified, evaluated and analyzed the radiation dose to which tumors and normal tissues were exposed in 3D conformal radiation therapy (CRT), intensity-modulated radiation therapy (IMRT) and tomotherapy by using a dose volume histogram (DVH) that represented the volume dose and the dose distribution of anatomical structures in the evaluation of treatment planning. Furthermore, a comparison was made for the dose to the gross tumor volume (GTV) and the planning target volume (PTV) of organ to be treated based on the change in field size for three-and four-dimensional computed tomography (3D-CT and 4D-CT) (gating based) and in the histogram with a view to proving the usefulness of 4D-CT therapy, which corresponds to respiration-gated radiation therapy. According to the study results, a comparison of 3D CRT, IMRT with a linear accelerator (LINAC), and tomotherapy demonstrated that the GTV of the cranium was higher for tomotherapy than for 3D CRT and IMRT with a LINAC by 5.2% and 4.6%, respectively. The GTV of the neck was higher for tomotherapy than for 3D CRT and IMRT with a LINAC by 6.5% and 2.0%, respectively. The GTV of the pelvis was higher for tomotherapy than for 3D CRT and IMRT with a LINAC by 8.6% and 3.7%, respectively. When the comparison was made for the 3D-CT and the 4D-CT (gating based) treatment equipment, the GTV and the PTV became smaller for 4D-CT treatment planning than for 3D-CT, which could reduce the area in which normal tissues in the surroundings are exposed to an unnecessary radiation dose. In addition, when 4D-CT treatment planning (gating based) was used, the radiation dose could be concentrated on the GTV, CTV or PTV, which meant that the treatment area exceeded that when 3D-CT's treatment planning was used. Moreover, the radiation dose on nearby normal tissues could be reduced. When 4D-CT treatment planning (gating based) was utilized, unnecessary areas that were exposed to a radiation dose could be reduced more than they could when 3D-CT treatment planning was utilized. This helped concentrate the radiation dose on the treatment area and, at the same time, reduce the radiation dose to which nearby normal tissues were exposed.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Computer Science and Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, HAE KAG photo

Lee, HAE KAG
College of Engineering (Department of Computer Science and Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE