Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

심정지 환자에서 기관 내관의 위치 확인을 위한 방법으로 연속 파형 이산화탄소 측정법과 초음파의 비교: 전향적 관찰 연구Comparison of Airway Ultrasonography and Continuous Waveform Capnography to Confirm Endotracheal Tube Placement in Cardiac Arrest Patients: Prospective Observational Study

Other Titles
Comparison of Airway Ultrasonography and Continuous Waveform Capnography to Confirm Endotracheal Tube Placement in Cardiac Arrest Patients: Prospective Observational Study
Authors
노종갑조영순김호중
Issue Date
2012
Publisher
대한응급의학회
Keywords
Ultrasonography; Cardiac arrest; Intubation
Citation
대한응급의학회지, v.23, no.5, pp.618 - 623
Journal Title
대한응급의학회지
Volume
23
Number
5
Start Page
618
End Page
623
URI
https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/15603
ISSN
1226-4334
Abstract
Purpose: The aim of this study was to assess the accuracy and timeliness of using tracheal ultrasound for examination of endotracheal tube placement in cardiac arrest patients. Methods: This was a prospective, observational study,conducted at the emergency department of a university teaching hospital. Patients underwent emergency intubation due to cardiac arrest. Airway ultrasonography was performed during emergency intubation with the transducer placed transversely at the trachea over the suprasternal notch. Quantitative waveform capnography was used as the criterion standard for confirmation of tracheal intubation. The main outcome was the timeliness between airway ultrasonography and capnography. Results: A total of 16 patients and 19 intubations were included in the analysis. The endotracheal tube was placed in the trachea in 16 intubations and in the esophagus in three intubations. The overall sensitivity and specificity of ultrasound for confirmation of tracheal intubation was 100%, respectively. The capnography application time after intubation was 17.5(10.0~32.5) seconds. The capnograpny confirmation time after application was 30(10~120) seconds. The ultrasound confirmation time for endotracheal tube placement after application was 5(4~5) seconds. Conclusion: When patients were in a low pulmonary blood flow state, such as cardiac arrest, capnography confirmation of endotracheal tube placement was not rapid and needed a lot of times. Ultrasound confirmation was very rapid and accurate, and was not affected by pulmonary blood flow. Ultrasound confirmation of endotracheal tube placement is more useful in the emergency department.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Emergency Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Ho Jung photo

Kim, Ho Jung
College of Medicine (Department of Emergency Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE