Development of MRI Scanning Technique that is Comfortable for Patients with Anxiety Disorder
- Authors
- Cho, Moo-Seong; Cho, Jae-Hwan; Chang, Yong-Min; Cho, Yong-Ho; Zeon, Seok-Kil; Dong, Kyung-Rae; Chung, Woon-Kwan; Lee, Hae-Kag; Kim, Hyun-Ju; Bae, Jae-Young; Ahn, Jae-Ouk; Lee, Sang-Jeong
- Issue Date
- Dec-2011
- Publisher
- 한국자기학회
- Keywords
- anxiety disorder; focusing board assembly; alpha wave; relaxation effect
- Citation
- Journal of Magnetics, v.16, no.4, pp 350 - 362
- Pages
- 13
- Journal Title
- Journal of Magnetics
- Volume
- 16
- Number
- 4
- Start Page
- 350
- End Page
- 362
- URI
- https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/16076
- DOI
- 10.4283/JMAG.2011.16.4.350
- ISSN
- 1226-1750
2233-6656
- Abstract
- The principal objective of this study was to develop a scanning technique that helps patients reduce their anxiety and relax their physical tension in the MRI system. The study targeted 10 healthy persons with no medical history of anxiety disorder in the past and with no current clinically diagnosed anxiety disorder, as well as 10 patients who were currently experiencing an anxiety disorder during the MRI scanning. The focusing board assembly was self-manufactured to conduct a clinical experiment via MRI scans. As a method to confirm the efficacy of the experiment, the bio meter was used to measure brainwaves from the study targets that were divided into the normal person group (A), who felt no anxiety in the MRI system and the experimental group, (B) who did experience anxiety in the MRI system. The two groups were compared between the cases in which the focusing board assembly was used and not used after measurements were conducted using the model MRI system and the bio meter. According to the comparison and analysis results, low measurements of the alpha wave indicate highly effective relaxation of tension. In the normal person group, the alpha wave measurement showed almost no difference between cases in which the focusing board assembly was used and cases in which it was not used. In the experimental group, the alpha wave measurements were lower in cases in which the focusing board assembly was used than in cases in which the focusing board assembly was not used; this was indicative of a profound relaxation effect.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - College of Medical Sciences > Department of Medical IT Engineering > 1. Journal Articles
- College of Engineering > Department of Computer Science and Engineering > 1. Journal Articles
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.