Detailed Information

Cited 0 time in webofscience Cited 2 time in scopus
Metadata Downloads

Interobserver variability in clinical target volume delineation in anal squamous cell carcinomaopen access

Authors
Kim, Kyung SuCheong, Kwang-HoKim, KyuboKoo, TaeryoolKoh, Hyeon KangChang, Ji HyunChang, Ah RamPark, Hae Jin
Issue Date
2-Feb-2021
Publisher
Nature Publishing Group
Citation
Scientific Reports, v.11, no.1
Journal Title
Scientific Reports
Volume
11
Number
1
URI
https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/18988
DOI
10.1038/s41598-021-82541-5
ISSN
2045-2322
Abstract
We evaluated the inter-physician variability in the target contouring of the radiotherapy for anal squamous cell carcinoma (ASCC). Clinical target volume (CTV) of three patients diagnosed with ASCC was delineated by seven experienced radiation oncologists from multi-institution. These patients were staged as pT1N1a, cT2N0, and cT4N1a, respectively, according to 8(th) edition of the American Joint Committee on Cancer staging system. Expert agreement was quantified using an expectation maximization algorithm for Simultaneous Truth and Performance Level Estimation (STAPLE). The maximum distance from the boundaries of the STAPLE generated volume with confidence level of 80% to those of the contour of each CTV in 6 directions was compared. CTV of pelvis which includes primary tumor, perirectal tissue and internal/external iliac lymph node (LN) area (CTV-pelvis) and CTV of inguinal area (CTV-inguinal) were obtained from the seven radiation oncologists. One radiation oncologist did not contain inguinal LN area in the treatment target volume of patient 2 (cT2N0 stage). CTV-inguinal displayed moderate agreement for each patient (overall kappa 0.58, 0.54 and 0.6, respectively), whereas CTV-pelvis showed substantial agreement (overall kappa 0.66, 0.68 and 0.64, respectively). Largest variation among each contour was shown in the inferior margin of the CTV-inguinal. For CTV-pelvis, anterior and superior margin showed the biggest variation. Overall, moderate to substantial agreement was shown for CTV delineation. However, large variations in the anterior and cranial boarder of the CTV-pelvis and the caudal margin of the CTV-inguinal suggest that further studies are needed to establish a clearer target volume delineation guideline.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Radiation Oncology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Chang, Ah Ram photo

Chang, Ah Ram
College of Medicine (Department of Radiation Oncology)
Read more

Altmetrics

Total Views & Downloads

BROWSE