Detailed Information

Cited 0 time in webofscience Cited 1 time in scopus
Metadata Downloads

Standardization Status of Total Cholesterol Concentration Measurement: Analysis of Korean External Quality Assessment Data

Authors
Yoon, Young AhnLee, Yong-WhaKim, SollipLee, KyunghoonPark, Hyung-DooChun, SailMin, Won-Ki
Issue Date
Jul-2021
Publisher
대한진단검사의학회
Keywords
Inaccuracy; Total cholesterol; External quality assessment; Standardization
Citation
Annals of Laboratory Medicine, v.41, no.4, pp 366 - 371
Pages
6
Journal Title
Annals of Laboratory Medicine
Volume
41
Number
4
Start Page
366
End Page
371
URI
https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/1939
DOI
10.3343/alm.2021.41.4.366
ISSN
2234-3806
2234-3814
Abstract
Background: Total cholesterol concentration measurement is important in the diagnosis of dyslipidemia and evaluation of cardiovascular disease risk factors. Measurement reliability for obtaining an accurate total cholesterol concentration requires procedure standardization. We evaluated the standardization status for total cholesterol concentration measurement through Korean external quality assessment (EQA) data analysis. Methods: This study involved 1,670 laboratories that participated in the EQA of total cholesterol concentration measurements in 2019 for 32 products from different manufacturers. The target concentrations of three quality control (QC) materials (samples A, B, and C) were measured using the reference method and compared with EQA data. The performance criteria for total cholesterol concentration measurement were based on the National Cholesterol Education Program guidelines, with +/- 3% inaccuracy. Results: The target values and inaccuracies of the QC material based on the reference method measurements were 254.65 +/- 7.64, 108.30 +/- 3.25, and 256.29 +/- 7.69 mg/dL (6.59 +/- 0.20, 2.80 +/- 0.08, and 6.63 +/- 0.20 mmol/L) for samples A, B, and C, respectively. The performance criteria were not met in 42.7% laboratories for sample A, 68.4% of laboratories for sample B, and 38.0% laboratories for sample C. Conclusions: Despite significant efforts to accurately measure total cholesterol concentrations, further actions are needed for measurement standardization. Manufacturers reporting values that differ from target values should check calibrator traceability; additional efforts to accurately measure total cholesterol concentrations are required for laboratories that use products from these manufacturers.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Clinical Pathology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yoon, Young Ahn photo

Yoon, Young Ahn
College of Medicine (Department of Clinical Pathology)
Read more

Altmetrics

Total Views & Downloads

BROWSE