Modified non-flared fully covered self-expandable metal stent for preoperative biliary drainage in pancreatic cancer
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Shin, Il Sang | - |
dc.contributor.author | Moon, Jong Ho | - |
dc.contributor.author | Lee, Yun Nah | - |
dc.contributor.author | Chung, Jun Chul | - |
dc.contributor.author | Jeong, Jaehong | - |
dc.contributor.author | Choi, Seo-Youn | - |
dc.contributor.author | Lee, Tae Hoon | - |
dc.contributor.author | Yang, Jae Kook | - |
dc.contributor.author | Cha, Sang-Woo | - |
dc.contributor.author | Cho, Young Deok | - |
dc.contributor.author | Park, Sang-Heum | - |
dc.date.accessioned | 2022-05-24T02:50:04Z | - |
dc.date.available | 2022-05-24T02:50:04Z | - |
dc.date.issued | 2022-01 | - |
dc.identifier.issn | 0815-9319 | - |
dc.identifier.issn | 1440-1746 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/20790 | - |
dc.description.abstract | Background and Aim Durable biliary drainage is essential in patients with pancreatic cancer in the era of effective neoadjuvant chemotherapy (NACT). Plastic stent (PS) tends to occlude easily, and current metal stents are designed for nonresectable cancer. We evaluated the efficacy of a modified non-flared fully covered self-expandable metal stent (M-FCSEMS) during the perioperative period in patients with resectable or borderline resectable pancreatic cancer. Methods Consecutive patients with resectable or borderline resectable pancreatic ductal adenocarcinoma had a 12-mm M-FCSEMS (M-FCSEMS group) or 7-Fr PS (PS group) placed for biliary decompression before NACT or curative-intent surgery. The primary outcome was the re-intervention rate, and secondary outcomes were technical success, stent patency, and adverse events (AEs). Results Endoscopic stent placement was technically successful in all 60 patients. Twenty-three patients underwent surgery and 37 NACT before surgery. Re-intervention was performed in 10.0% (3/30) of patients in the M-FCSEMS group and 36.7% (11/30) of patients in the PS group (P = 0.030). The stent patency at 180 days was 89.8% (95% confidence interval, 77.3-100.0%) in the M-FCSEMS group and 30.2% (95% confidence interval, 11.4-80.0%) in the PS group (P < 0.0001). Stent-related AEs occurred in 10.0% (3/30) in the M-FCSEMS group and 40.0% (12/30) in the PS group (P = 0.015). Surgery-related AEs occurred in 10.5% (2/19) and 14.3% (3/21) in the M-FCSEMS and PS groups (P = 0.549). Conclusions Modified non-flared fully covered self-expandable metal stents are effective and safe for durable biliary drainage in patients with resectable or borderline resectable pancreatic cancer during the perioperative period. | - |
dc.format.extent | 8 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | Blackwell Publishing Inc. | - |
dc.title | Modified non-flared fully covered self-expandable metal stent for preoperative biliary drainage in pancreatic cancer | - |
dc.type | Article | - |
dc.publisher.location | 미국 | - |
dc.identifier.doi | 10.1111/jgh.15733 | - |
dc.identifier.scopusid | 2-s2.0-85119455214 | - |
dc.identifier.wosid | 000720304400001 | - |
dc.identifier.bibliographicCitation | Journal of Gastroenterology and Hepatology, v.37, no.1, pp 225 - 232 | - |
dc.citation.title | Journal of Gastroenterology and Hepatology | - |
dc.citation.volume | 37 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 225 | - |
dc.citation.endPage | 232 | - |
dc.type.docType | Article | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Gastroenterology & Hepatology | - |
dc.relation.journalWebOfScienceCategory | Gastroenterology & Hepatology | - |
dc.subject.keywordPlus | INTERNATIONAL STUDY-GROUP | - |
dc.subject.keywordPlus | STRICTURES | - |
dc.subject.keywordPlus | OBSTRUCTION | - |
dc.subject.keywordPlus | DEFINITION | - |
dc.subject.keywordPlus | MANAGEMENT | - |
dc.subject.keywordPlus | PLACEMENT | - |
dc.subject.keywordPlus | MIGRATION | - |
dc.subject.keywordPlus | PAPILLA | - |
dc.subject.keywordAuthor | Covered self-expandable metal stent | - |
dc.subject.keywordAuthor | Drainage | - |
dc.subject.keywordAuthor | Pancreatic neoplasms | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(31538) 22, Soonchunhyang-ro, Asan-si, Chungcheongnam-do, Republic of Korea+82-41-530-1114
COPYRIGHT 2021 by SOONCHUNHYANG UNIVERSITY ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.