Detailed Information

Cited 0 time in webofscience Cited 1 time in scopus
Metadata Downloads

Modified non-flared fully covered self-expandable metal stent for preoperative biliary drainage in pancreatic cancer

Authors
Shin, Il SangMoon, Jong HoLee, Yun NahChung, Jun ChulJeong, JaehongChoi, Seo-YounLee, Tae HoonYang, Jae KookCha, Sang-WooCho, Young DeokPark, Sang-Heum
Issue Date
Jan-2022
Publisher
Blackwell Publishing Inc.
Keywords
Covered self-expandable metal stent; Drainage; Pancreatic neoplasms
Citation
Journal of Gastroenterology and Hepatology, v.37, no.1, pp 225 - 232
Pages
8
Journal Title
Journal of Gastroenterology and Hepatology
Volume
37
Number
1
Start Page
225
End Page
232
URI
https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/20790
DOI
10.1111/jgh.15733
ISSN
0815-9319
1440-1746
Abstract
Background and Aim Durable biliary drainage is essential in patients with pancreatic cancer in the era of effective neoadjuvant chemotherapy (NACT). Plastic stent (PS) tends to occlude easily, and current metal stents are designed for nonresectable cancer. We evaluated the efficacy of a modified non-flared fully covered self-expandable metal stent (M-FCSEMS) during the perioperative period in patients with resectable or borderline resectable pancreatic cancer. Methods Consecutive patients with resectable or borderline resectable pancreatic ductal adenocarcinoma had a 12-mm M-FCSEMS (M-FCSEMS group) or 7-Fr PS (PS group) placed for biliary decompression before NACT or curative-intent surgery. The primary outcome was the re-intervention rate, and secondary outcomes were technical success, stent patency, and adverse events (AEs). Results Endoscopic stent placement was technically successful in all 60 patients. Twenty-three patients underwent surgery and 37 NACT before surgery. Re-intervention was performed in 10.0% (3/30) of patients in the M-FCSEMS group and 36.7% (11/30) of patients in the PS group (P = 0.030). The stent patency at 180 days was 89.8% (95% confidence interval, 77.3-100.0%) in the M-FCSEMS group and 30.2% (95% confidence interval, 11.4-80.0%) in the PS group (P < 0.0001). Stent-related AEs occurred in 10.0% (3/30) in the M-FCSEMS group and 40.0% (12/30) in the PS group (P = 0.015). Surgery-related AEs occurred in 10.5% (2/19) and 14.3% (3/21) in the M-FCSEMS and PS groups (P = 0.549). Conclusions Modified non-flared fully covered self-expandable metal stents are effective and safe for durable biliary drainage in patients with resectable or borderline resectable pancreatic cancer during the perioperative period.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Internal Medicine > 1. Journal Articles
College of Medicine > Department of Internal Medicine > 1. Journal Articles
College of Medicine > Department of Radiology > 1. Journal Articles
College of Medicine > Department of General Surgery > 1. Journal Articles
College of Medicine > Department of Internal Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Yun Nah photo

Lee, Yun Nah
College of Medicine (Department of Internal Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE