Detailed Information

Cited 0 time in webofscience Cited 4 time in scopus
Metadata Downloads

Perovskite lanthanum nickelate nanoparticles: As effective modified screen printed carbon electrode for electrochemical detection of trifluoperazine

Authors
Pandiyan, RajaramVinothkumar, VenkatachalamChen, Shen -MingPrasad, Gajapaneni VenkataKim, Tae Hyun
Issue Date
Jun-2023
Publisher
Elsevier
Keywords
Perovskites; Rare earth nickelates; Trifluoperazine; Electrochemical sensor; Biological samples
Citation
Surfaces and Interfaces, v.38
Journal Title
Surfaces and Interfaces
Volume
38
URI
https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/22411
DOI
10.1016/j.surfin.2023.102805
ISSN
2468-0230
Abstract
Perovskite rare earth nickelates have recently been considered excellent electroanalytical features for sensing a variety of target molecules due to their distinctive properties. In this work, a facile coprecipitation synthesis of perovskite lanthanum nickelate (LaNiO3, LNO) nanoparticles was reported along with its application to the electrochemical sensing of trifluoperazine (TFP). The crystal structure and surface morphology of the LNO was characterized by suitable techniques such as X-ray diffraction (XRD), Fourier transform infrared spectrometry (FTIR), X-ray photoelectron spectroscopy (XPS), field emission scanning electron microscopy (FESEM), and transmission electron microscopy (TEM) with energy-dispersive X-ray (EDX) analysis. The capability of the modified screen printed carbon electrode (LNO/SPCE) to detect TFP in 0.1 M PBS (pH 7) was then examined using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods. The electrode modified at 0.759 V vs Ag/AgCl and 30 s exhibited the highest peak current (Ip) for TFP electrooxidation. This optimized electrode showed a broad linear range of 0.165-495.5 mu M, a low limit of detection (LOD) of 0.017 mu M, and a good sensitivity of 0.704 mu A mu M-1 cm-2. Moreover, the fabricated sensor revealed promising anti-interfering ability, stability, reproducibility, and repeatability toward TFP detection. Finally, the LNO sensor was able to detect TFP in urine and serum samples, and the recovery rates were satisfactory.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Natural Sciences > Department of Chemistry > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Tae Hyun photo

Kim, Tae Hyun
College of Natural Sciences (Department of Chemistry)
Read more

Altmetrics

Total Views & Downloads

BROWSE