Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Immediate and Late Effects of Pulse Widths and Cycles on Bipolar, Gated Radiofrequency-Induced Tissue Reactions in in vivo Rat Skinopen access

Authors
Kim, Hee KyungKim, Hyun-JoKim, Jae YunBan, Myung JinSon, JiwonHwang, YongsungBin Cho, Sung
Issue Date
Apr-2023
Publisher
Dove Medical Press Limited
Keywords
radiofrequency; bipolar; alternating current; gated pulse; tissue reaction; rat
Citation
Clinical, Cosmetic and Investigational Dermatology, v.16, pp 721 - 729
Pages
9
Journal Title
Clinical, Cosmetic and Investigational Dermatology
Volume
16
Start Page
721
End Page
729
URI
https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/22416
DOI
10.2147/CCID.S404631
ISSN
1178-7015
Abstract
Background: Single to multiple pulse packs of bipolar, alternating current radiofrequency (RF) oscillations have been used for various medical purposes using invasive microneedle electrodes. This study was designed to evaluate the effects of pulse widths and cycles of RF pulse packs on immediate and delayed thermal tissue reactions in in vivo rat skin.Methods: RF energy at the frequency of 1 MHz and power of 70 W was delivered at each experimental setting into in vivo rat skin at 1.5-mm microneedle penetration, and then, tissue samples were obtained after 1 h and 3, 7, 14, and 21 days and histologically analyzed.Results: A single-pulse-pack RF treatment generated coagulative necrosis zones in the dermal peri-electrode area and zones of non -necrotic thermal reactions in the dermal inter-electrode area. Multiple pulse-pack, RF-treated rat skin specimens revealed that the number and size of peri-electrode coagulative necrosis were markedly decreased by increasing the number of pulse packs and accordingly decreasing the conduction time of each pulse pack. The microscopic changes in RF-induced non-necrotic thermal reaction in the inter-electrode area were more remarkable in specimens treated with RF of 7 or 10 pulse packs than in specimens treated with RF of 1-4 pulse packs.Conclusion: The gated delivery of multiple RF pulse packs using a bipolar, alternating current, 1-MHz RF system using insulated microneedle electrodes efficiently generates non-necrotic thermal tissue reactions over the upper, mid, and deep dermis and subcutaneous fat in the inter-electrode areas.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Integrated Biomedical Science > 1. Journal Articles
College of Medicine > Department of Otorhinolaryngology > 1. Journal Articles
SCH Media Labs > Department of Big Data Engineering > 1. Journal Articles
College of Medicine > Department of Pathology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Hee Kyung photo

Kim, Hee Kyung
College of Medicine (Department of Pathology)
Read more

Altmetrics

Total Views & Downloads

BROWSE