Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Efficacy of a newly developed guidewire for selective biliary accessopen access

Authors
Park, Do HyunHan, Joung-HoLee, Tae HoonYang, Jae KookLee, Ji SungLee, Yong HunTakenaka, MamoruPark, Sang-Heum
Issue Date
May-2023
Publisher
Nature Publishing Group
Citation
Scientific Reports, v.13, no.1
Journal Title
Scientific Reports
Volume
13
Number
1
URI
https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/25172
DOI
10.1038/s41598-023-34846-w
ISSN
2045-2322
Abstract
A clinical efficacy study of 0.025-inch guidewires (GWs) according to mechanical property analysis has not been reported yet. This study was designed to evaluate the clinical efficacy of a newly developed 0.025-inch GW for biliary access according to the basic mechanical property. Commercially available 0.025-inch GWs were in vitro tested based on parameters of mechanical property. Patients with naive papilla requiring diagnostic or therapeutic ERCP were randomly assigned to an experimental 0.025-inch newly developed GW or a control 0.025-inch GW group. Technical success rate of wire-guided cannulation (WGC), difficult biliary cannulation (DBC), and adverse event rates were measured in this multicenter randomized trial. The technical success rate of primary WGC was 79.1% (151 of 191) in the experimental group and 70.8% (131 of 185) in the control group (95% two-sided confidence interval: 8.25%; p < 0.001; for a noninferiority margin of 15%). The technical success rate including cross-over to each other was also non-inferior. However, the chi-square test showed a statistical difference (81.7% vs. 68.1%; p = 0.002). Median biliary cannulation time was shorter in the experimental group (53 s vs. 77 s; p = 0.047). The rate of DBC was more frequent in the control group (34.6% vs. 50.3% p = 0.002). Multivariate analysis revealed that control group was one of contributing factors for DBC. Overall rate of post-ERCP pancreatitis was not different (4.7% vs. 8.6%; p = 0.125). WGC using a newly developed GW with superior physical performance GW in a bench test showed similar clinical efficacy and the rate of DBC was significantly lower in experimental GW.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Internal Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher YANG, JAE KOOK photo

YANG, JAE KOOK
College of Medicine (Department of Internal Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE