액체크로마토그래피-질량분석법 기반 전혈 내 면억억제제 약물농도 정량검사에 접목한 Andrew+ 검체 로봇 전처리방법 평가

Full metadata record
DC Field Value Language
dc.contributor.author채효진-
dc.contributor.author김혜정-
dc.contributor.author김정은-
dc.contributor.author이정중-
dc.contributor.author조성은-
dc.contributor.author김솔잎-
dc.contributor.author이경훈-
dc.contributor.author이상국-
dc.contributor.author이용화-
dc.contributor.author박형두-
dc.contributor.author박승만-
dc.contributor.author송상훈-
dc.contributor.author전사일-
dc.contributor.author송정한-
dc.contributor.author대한임상화학회 임상질량분석연구회-
dc.date.accessioned2023-12-14T07:01:02Z-
dc.date.available2023-12-14T07:01:02Z-
dc.date.issued2023-07-
dc.identifier.urihttps://scholarworks.bwise.kr/sch/handle/2021.sw.sch/25743-
dc.description.abstractBackground: Liquid chromatography/tandem mass spectrometry (LC-MS/MS)-based assays are increasingly being used for therapeutic drug monitoring (TDM) of immunosuppressive drugs (ISDs). However, many laboratories that employ LC-MS/MS assays for TDM of ISDs use manual sample preparation steps. Methods: We implemented a semi-automated sample preparation method based on protein precipitation, using an Andrew+ liquid handler, integrated with an LC-MS/MS-based TDM assay for four ISDs (tacrolimus, sirolimus, everolimus, and cyclosporine A). The feasibility and analytical performance were analyzed and compared with those of the manual sample preparation method using 163 clinical samples. Results: The total execution time of Andrew+-based sample preparation method was 55 minutes (including off-line centrifugation) for 48 samples. However, the hands-on time was significantly reduced than that of the manual sample preparation method. The average repeatability and within-laboratory precision of the assay were acceptable (CV ≤10%), and the results of manual and Andrew+-based sample preparation methods were equivalent. Conclusions: The sample preparation method using the Andrew+ liquid handler was successfully integrated with LC-MS/MS-based TDM assays for ISDs. Sample preparation using Andrew+ was reproducible, standardized, and enabled excellent utilization of technical staff time. Although further optimization for full automation is still pursued, this study indicates the potential of integrating liquid handers with LC-MS/MS-based assays in the clinical setting.-
dc.format.extent6-
dc.language영어-
dc.language.isoENG-
dc.publisher대한진단검사의학회-
dc.title액체크로마토그래피-질량분석법 기반 전혈 내 면억억제제 약물농도 정량검사에 접목한 Andrew+ 검체 로봇 전처리방법 평가-
dc.title.alternativeEvaluation of a Robotic Liquid Handler, Andrew+, for Sample Preparation for LC-MS/MS-Based Quantitation of Immunosuppressants in Whole Blood-
dc.typeArticle-
dc.identifier.doi10.47429/lmo.2023.13.3.199-
dc.identifier.bibliographicCitationLaboratory Medicine Online, v.13, no.3, pp 199 - 204-
dc.citation.titleLaboratory Medicine Online-
dc.citation.volume13-
dc.citation.number3-
dc.citation.startPage199-
dc.citation.endPage204-
dc.identifier.kciidART002974612-
dc.description.isOpenAccessN-
dc.subject.keywordAuthorAutomated liquid handling-
dc.subject.keywordAuthorImmunosuppressive drug-
dc.subject.keywordAuthorLiquid chromatography/tandem mass spectrometry-
dc.subject.keywordAuthorSample preparation-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Clinical Pathology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Yong Wha photo

Lee, Yong Wha
College of Medicine (Department of Clinical Pathology)
Read more

Altmetrics

Total Views & Downloads

BROWSE