Detailed Information

Cited 0 time in webofscience Cited 8 time in scopus
Metadata Downloads

Family-based case-control study of exposure to household humidifier disinfectants and risk of idiopathic interstitial pneumoniaopen access

Authors
Lamichhane, Dirga KumarLeem, Jong-HanLee, Sang-MinYang, Hyeon-JongKim, JaiyongLee, Jong-HyunKo, Jung KeunKim, Hwan CheolPark, Dong-UkCheong, Hae-Kwan
Issue Date
5-Sep-2019
Publisher
Public Library of Science
Keywords
Household humidifier disinfectants; Idiopathic interstitial pneumonia; Pediatrics
Citation
PLoS ONE, v.14, no.9
Journal Title
PLoS ONE
Volume
14
Number
9
URI
https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/4213
DOI
10.1371/journal.pone.0221322
ISSN
1932-6203
Abstract
Background In Korea, several household humidifier disinfectants (HDs) were clinically confirmed to cause HD-associated lung injury (HDLI). Polyhexamethylene guanidine (PHMG) phosphate is the main ingredient of the HDs found to be associated with lung disease. However, the association of HDs with other interstitial lung disease including idiopathic interstitial pneumonia (IIP) is not clear. We examined the relationship between HD exposure and IIP in a family-based study. Methods This case-control study included 244 IIP cases and 244 family controls who lived with the IIP patients. The IIP cases were divided into two groups, HDLI and other IIP, and were matched to family controls based on age and gender. Information on exposure to HDs was obtained from a structured questionnaire and field investigations. Conditional logistic regression was used to estimate odds ratio (ORs) and their corresponding 95% confidence interval (CI), investigating the association of HD-related exposure characteristics with IIP risk. Results The risks of IIP increased two-fold or more in the highest compared with the lowest quartile of several HD use characteristics, including average total use hours per day, cumulative sleep hours, use of HD during sleep, and cumulative exposure level. In analyses separated by HDLI and other IIP, the risks of HDLI were associated with airborne HD concentrations (adjusted OR = 3.01, 95% CI = 1.34-6.76; Q4 versus Q1) and cumulative exposure level (adjusted OR = 3.57, 95% CI = 1.59-8.01; Q4 versus Q1), but this relationship was not significant in the patients with other IIP. In comparison between HDLI and other IIP, the odds ratios of average total use hours, cumulative use hours, and cumulative sleeps hours was higher for other IIP. Conclusion The use of household HDs is associated not only with HDLI but also with other IIP.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Pediatrics > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yang, Hyeon Jong photo

Yang, Hyeon Jong
College of Medicine (Department of Pediatrics)
Read more

Altmetrics

Total Views & Downloads

BROWSE