Detailed Information

Cited 0 time in webofscience Cited 14 time in scopus
Metadata Downloads

Quantitation of 2-acetyl-1-pyrroline in aseptic-packaged cooked fragrant rice by HS-SPME/GC-MSopen access

Authors
Lee, Young-SangOh, YejinKim, Tae-HyungCho, Yoo-Hyun
Issue Date
Jan-2019
Publisher
John Wiley and Sons Ltd
Keywords
2-acetyl-1-pyrroline; aseptic package; fragrant rice; standard addition
Citation
Food Science and Nutrition, v.7, no.1, pp 266 - 272
Pages
7
Journal Title
Food Science and Nutrition
Volume
7
Number
1
Start Page
266
End Page
272
URI
https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/4817
DOI
10.1002/fsn3.879
ISSN
2048-7177
Abstract
Aseptic-packaged cooked rice (APCR) is a rice-based food product with a rapidly increasing market size, and APCR made of fragrant rice (FR) has recently appeared on the market. The fragrance of FR is produced by a combination of odoriferous compounds, among which 2-acetyl-1-pyrroline (2AP) has been identified as the most important contributor to overall aroma. This study describes the development of a method to quantify 2AP in FR-based APCR using headspace solid-phase microextraction (SPME) coupled with gas chromatography-mass spectrometry (GC-MS). The recovery of 2AP spiked into APCR was lower than 10%, which suggests significant matrix effects and inappropriateness of external standard-based calibration. For standard addition calibration method, up to 1,000 ng of 2AP were spiked into APCR containing 0% to 100% FR. Subsequent regression analyses of recovered peak area (Y) as a function of the amount of 2AP spiked (X) yielded highly linear calibration curves (R-2 > 0.9917) with consistent slopes (RSD = 2.7%), regardless of FR composition. Y-intercepts, however, which represent the amount of 2AP in APCR without spiking, increased linearly (R-2 = 0.9898) in proportion to the composition of FR in the APCR. The amount of 2AP in APCR, determined by extrapolating the standard addition calibration curves, also increased linearly (R-2 = 0.9963) as a function of FR composition. Practicality of developed method was tested by monitoring 2AP contents in APCR under realistic storage conditions, which successfully demonstrated 38% and 60% 2AP reductions in APCR of 20% FR after 1 and 2 months of storage at 25 degrees C, respectively. The present study demonstrates that a standard addition method, whereby up to 1,000 ng of 2AP standard is spiked into 4 g of APCR containing 5%-100% FR in a 20-mL headspace vial followed by SPME/GC-MS, may serve as an effective means of quantitating 2AP in fragrant rice-based APCR.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medical Sciences > Department of Medical Biotechnology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Young Sang photo

Lee, Young Sang
College of Medical Sciences (Department of Medical Biotechnology)
Read more

Altmetrics

Total Views & Downloads

BROWSE