Detailed Information

Cited 0 time in webofscience Cited 6 time in scopus
Metadata Downloads

Visibility of bony structures around hip prostheses in dual-energy CT: With or without metal artefact reduction software

Full metadata record
DC Field Value Language
dc.contributor.authorJeong, Jewon-
dc.contributor.authorKim, Hyun-joo-
dc.contributor.authorOh, Eunsun-
dc.contributor.authorCha, Jang Gyu-
dc.contributor.authorHwang, Jiyoung-
dc.contributor.authorHong, Seong Sook-
dc.contributor.authorChang, Yun Woo-
dc.date.accessioned2021-08-11T11:43:41Z-
dc.date.available2021-08-11T11:43:41Z-
dc.date.issued2018-10-
dc.identifier.issn1754-9477-
dc.identifier.issn1754-9485-
dc.identifier.urihttps://scholarworks.bwise.kr/sch/handle/2021.sw.sch/5603-
dc.description.abstractIntroduction: The development of dual-energy CT and metal artefact reduction software provides a further chance of reducing metal-related artefacts. However, there have been only a few studies regarding whether MARs practically affect visibility of structures around a metallic hip prosthesis on post-operative CT evaluation. Methods: Twenty-seven patients with 42 metallic hip prostheses underwent DECT. The datasets were reconstructed with 70, 90 and 110 keV with and without MARs. The areas were classified into 10 zones according to the reference zone. All the images were reviewed in terms of the severity of the beam-hardening artefacts, differentiation of the bony cortex and trabeculae and visualization of trabecular patterns with a three-point scale. The metallic screw diameter was measured in the acetabulum with 110 keV images. Results: The scores were the worst on 70 keV images without MARs [mean scores:1.84-4.22 (p < 0.001-1.000)]. The structures in zone II were best visualized on 110 keV (p < 0.001-0.011, mean scores: 2.86-5.22). In other zones, there is general similarity in mean scores whether applying MARs or not (p < 0.001-0.920). The mean diameter of the screw was 5.85 mm without MARs and 3.44 mm with MARs (mean reference diameter: 6.48 mm). Conclusion: The 110 keV images without MARs are best for evaluating acetabular zone II. The visibility of the bony structures around the hip prosthesis is similar in the other zones with or without MARs regardless of key. MARS may not be needed for the evaluation of the metallic hip prosthesis itself at sufficient high-energy levels; however, MARS still has a role in the evaluation of other soft tissues around the prosthesis.-
dc.format.extent8-
dc.language영어-
dc.language.isoENG-
dc.publisherBlackwell Pub. Asia-
dc.titleVisibility of bony structures around hip prostheses in dual-energy CT: With or without metal artefact reduction software-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.1111/1754-9485.12746-
dc.identifier.scopusid2-s2.0-85047643002-
dc.identifier.wosid000446450600005-
dc.identifier.bibliographicCitationJournal of Medical Imaging and Radiation Oncology, v.62, no.5, pp 634 - 641-
dc.citation.titleJournal of Medical Imaging and Radiation Oncology-
dc.citation.volume62-
dc.citation.number5-
dc.citation.startPage634-
dc.citation.endPage641-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordPlusREVISION TOTAL HIP-
dc.subject.keywordPlusMRI GRADING SYSTEM-
dc.subject.keywordPlusUNITED-STATES-
dc.subject.keywordPlusFOLLOW-UP-
dc.subject.keywordPlusREPLACEMENT-
dc.subject.keywordPlusARTHROPLASTY-
dc.subject.keywordPlusEPIDEMIOLOGY-
dc.subject.keywordPlusTOMOGRAPHY-
dc.subject.keywordPlusPREVALENCE-
dc.subject.keywordPlusFRACTURES-
dc.subject.keywordAuthorCT-dual energy-
dc.subject.keywordAuthormetal artefact reduction software-
dc.subject.keywordAuthormetal hip prostheses-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Radiology > 1. Journal Articles
College of Medicine > Department of Radiology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Hwang, Ji young photo

Hwang, Ji young
College of Medicine (Department of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE