Visibility of bony structures around hip prostheses in dual-energy CT: With or without metal artefact reduction software

Authors
Jeong, JewonKim, Hyun-jooOh, EunsunCha, Jang GyuHwang, JiyoungHong, Seong SookChang, Yun Woo
Issue Date
Oct-2018
Publisher
Blackwell Pub. Asia
Keywords
CT-dual energy; metal artefact reduction software; metal hip prostheses
Citation
Journal of Medical Imaging and Radiation Oncology, v.62, no.5, pp 634 - 641
Pages
8
Journal Title
Journal of Medical Imaging and Radiation Oncology
Volume
62
Number
5
Start Page
634
End Page
641
URI
https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/5603
DOI
10.1111/1754-9485.12746
ISSN
1754-9477
1754-9485
Abstract
Introduction: The development of dual-energy CT and metal artefact reduction software provides a further chance of reducing metal-related artefacts. However, there have been only a few studies regarding whether MARs practically affect visibility of structures around a metallic hip prosthesis on post-operative CT evaluation. Methods: Twenty-seven patients with 42 metallic hip prostheses underwent DECT. The datasets were reconstructed with 70, 90 and 110 keV with and without MARs. The areas were classified into 10 zones according to the reference zone. All the images were reviewed in terms of the severity of the beam-hardening artefacts, differentiation of the bony cortex and trabeculae and visualization of trabecular patterns with a three-point scale. The metallic screw diameter was measured in the acetabulum with 110 keV images. Results: The scores were the worst on 70 keV images without MARs [mean scores:1.84-4.22 (p < 0.001-1.000)]. The structures in zone II were best visualized on 110 keV (p < 0.001-0.011, mean scores: 2.86-5.22). In other zones, there is general similarity in mean scores whether applying MARs or not (p < 0.001-0.920). The mean diameter of the screw was 5.85 mm without MARs and 3.44 mm with MARs (mean reference diameter: 6.48 mm). Conclusion: The 110 keV images without MARs are best for evaluating acetabular zone II. The visibility of the bony structures around the hip prosthesis is similar in the other zones with or without MARs regardless of key. MARS may not be needed for the evaluation of the metallic hip prosthesis itself at sufficient high-energy levels; however, MARS still has a role in the evaluation of other soft tissues around the prosthesis.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Radiology > 1. Journal Articles
College of Medicine > Department of Radiology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher OH, EUN SUN photo

OH, EUN SUN
College of Medicine (Department of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE