Indoor levels of volatile organic compounds and formaldehyde from emission sources at elderly care centers in Koreaopen access

Authors
Lee, KyounghoChoi, Jae-HyunLee, SeokwonPark, Hee-JinOh, Yu-JinKim, Geun-BaeLee, Woo-SeokSon, Bu-Soon
Issue Date
7-Jun-2018
Publisher
Public Library of Science
Keywords
indoor; voc; elderly; care center
Citation
PLoS ONE, v.13, no.6
Journal Title
PLoS ONE
Volume
13
Number
6
URI
https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/5873
DOI
10.1371/journal.pone.0197495
ISSN
1932-6203
Abstract
The objective of this study is to characterize indoor and outdoor levels of volatile organic compounds (VOCs) and formaldehyde (HCHO) and identify indoor emission sources in thirty elderly care centers (ECCs) located in the Seoul metropolitan city and Gyeonggi province in Korea. Air monitoring samples from indoor and outdoor environments were collected from January to December in 2007. Statistical analyses of indoor and outdoor VOCs and HCHO levels in three rooms (a bedroom, living, and dining rooms) of each ECC were performed, and these were compared to identify environmental factors associated with an increase of indoor pollution levels. Total volatile organic compounds (TVOC) levels were significantly (p<0.05) different between indoor (230.7 +/- 1.7 mu g/m(3)) and outdoor (137.8 +/- 1.9 mu g/m(3)) environments, with an I/O ratio of 1.67. The indoor HCHO level (20.1 +/- 1.6 mu g/m(3)) was significantly (p<0.05) higher than the outdoor level (8.1 +/- 1.9 mu g/m(3)), with an I/O ratio of 2.48. Indoor VOCs and HCHO levels in the bedrooms were significantly (p<0.05) higher than those in the living and dining rooms. Furthermore, indoor levels of VOCs and HCHO at ECCs were significantly (p<0.05) different depending on environmental factors such as the use of carpet, paint, and wooden furniture. In multiple regression analysis, indoor VOCs and HCHO levels at ECCs were significantly (p<0.05) correlated with two micro-environmental factors: the use of carpet and paint. This study confirmed that indoor VOCs and HCHO levels were significantly higher than those in outdoor environments. These air pollutants were mainly emitted from indoor sources, such as carpet, paint, and construction materials at the ECCs in Korea.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Natural Sciences > Department of Environmental Health Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher SON, BU SOON photo

SON, BU SOON
College of Natural Sciences (Department of Environmental Health Science)
Read more

Altmetrics

Total Views & Downloads

BROWSE