국내 주요 대도시 소재 민감그룹 이용시설 실내공간의PM10, HCHO, TBC 농도에 관한 연구A Study on PM10, HCHO and TBC concentrations in the indoor space of sensitive group use public facilities located in major cities in Korea
- Other Titles
- A Study on PM10, HCHO and TBC concentrations in the indoor space of sensitive group use public facilities located in major cities in Korea
- Authors
- 안지희; 손부순; 오유진; 홍은주
- Issue Date
- 2018
- Publisher
- 한국냄새환경학회
- Keywords
- HCHO; Indoor air quality; PM10; TBC
- Citation
- 실내환경 및 냄새 학회지, v.17, no.3, pp.207 - 214
- Journal Title
- 실내환경 및 냄새 학회지
- Volume
- 17
- Number
- 3
- Start Page
- 207
- End Page
- 214
- URI
- https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/6528
- DOI
- 10.15250/joie.2018.17.3.207
- ISSN
- 2288-9167
- Abstract
- In this study, we measured the concentration of Particulate Matter (PM10), Formaldehyde (HCHO), and TotalBacteria Count (TBC) at three facilities: elderly care centers, day care centers, and postnatal care centers locatedin the cities of Seoul, Sejong, Daegu and Ulsan from January 1, 2012 to December 31, 2015. PM10 concentrationwas the highest in the day care centers and HCHO concentration was the highest in the postnatal care centers.
TBC concentration was the highest in the day care centers. Comparing the different cities, PM10 concentrationwas the highest in Sejong, HCHO concentration was the highest in Seoul, and TBC concentration was the highestin Daegu. This study is expected to be helpful in preventing damage to health from the contaminated indoor airat sensitive facilities, and can be used as basic data for indoor air quality management.