Detailed Information

Cited 0 time in webofscience Cited 9 time in scopus
Metadata Downloads

Validation of the Korean National Healthcare-associated Infections Surveillance System (KONIS): an intensive care unit module report

Authors
Kwak, Y. G.Choi, J. Y.Yoo, H. M.Lee, S-O.Kim, H. B.Han, S. H.Choi, H. J.Kim, S. R.Kim, T. H.Chun, H. K.Koo, H-S.
Issue Date
Aug-2017
Publisher
W. B. Saunders Co., Ltd.
Keywords
Validation; KONIS; Surveillance; Healthcare-associated; infections
Citation
Journal of Hospital Infection, v.96, no.4, pp 377 - 384
Pages
8
Journal Title
Journal of Hospital Infection
Volume
96
Number
4
Start Page
377
End Page
384
URI
https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/7351
DOI
10.1016/j.jhin.2017.04.003
ISSN
0195-6701
1532-2939
Abstract
Background: National surveillance data should be validated to identify methodological problems within the surveillance programme and data quality issues. Aim: To test the validity of healthcare-associated infection (HAI) rate data from the Korean National Healthcare-associated Infections Surveillance System (KONIS). Methods: Records from intensive care units of 12 (14.8%) of 81 participating hospitals for January-March 2014 were examined. The validation team reviewed 406 medical records of 110 patients with 114 reported HAIs - including 34 urinary tract infections (UTIs), 57 bloodstream infections (BSIs) and 23 cases of pneumonia (PNEU) - and 296 patients with no reported HAIs during one-day visits conducted in August and September 2014. The reviewers' diagnosis of HAI was regarded as the reference standard; in ambiguous cases, the KONIS Steering Committee confirmed the diagnosis of HAI. Findings: Sensitivity values for UTIs, BSIs and PNEU were 85.3%, 74.0% and 66.7%, and specificity values were 98.7%, 99.1% and 98.7%, respectively. Positive predictive values were 85.3%, 94.7% and 78.3%, and negative predictive values were 98.7%, 94.6% and 97.7%, respectively. Sensitivity for PNEU was lower than that for UTIs and BSIs. The hospitals participating in KONIS infrequently reported conditions that were not HAIs. Sensitivity for BSIs was lower in this study than in KONIS validation studies conducted in 2008 and 2010. Conclusions: KONIS data are generally reliable; however, sensitivity for BSIs exhibited a decrease. This study shows the need for ongoing validation and continuous training of surveillance personnel to maintain the accuracy of surveillance data. (C) 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Internal Medicine > 1. Journal Articles
College of Medicine > Department of Nursing > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Han, Su ha photo

Han, Su ha
College of Medicine (Department of Nursing)
Read more

Altmetrics

Total Views & Downloads

BROWSE