Detailed Information

Cited 0 time in webofscience Cited 23 time in scopus
Metadata Downloads

MRI of the anterior talofibular ligament, talar cartilage and os subfibulare: Comparison of isotropic resolution 3D and conventional 2D T2-weighted fast spin-echo sequences at 3.0 T

Authors
Yi, JisookCha, Jang GyuLee, Young KooLee, Bo RaJeon, Chan Hong
Issue Date
Jul-2016
Publisher
Springer Verlag
Keywords
Ankle; 3-Tesla; Isotropic magnetic resonance imaging; ATFL; Chondral lesion of the talus; Os subfibulare
Citation
Skeletal Radiology, v.45, no.7, pp 899 - 908
Pages
10
Journal Title
Skeletal Radiology
Volume
45
Number
7
Start Page
899
End Page
908
URI
https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/9007
DOI
10.1007/s00256-016-2367-x
ISSN
0364-2348
1432-2161
Abstract
To determine the accuracy of a three-dimensional (3D) T2-weighted fast spin-echo (FSE) magnetic resonance (MR) sequence compared with two-dimensional (2D) sequence for diagnosing anterior talofibular ligament (ATFL) tears, chondral lesion of the talus (CLT) and os subfibulare/avulsion fracture of the distal fibula (OSF). Thirty-five patients were included, who had undergone ankle MRI with 3D T2-weighted FSE and 2D T2-weighted FSE sequences, as well as subsequent ankle arthroscopy, between November 2013 and July 2014. Each MR imaging sequence was independently scored by two readers retrospectively for the presence of ATFL tears, CLT and OSF. The area under the receiver operating curve (AUC) was compared to determine the discriminatory power of the two image sequences. Interobserver agreement was expressed as unweighted kappa value. Arthroscopic findings confirmed 21 complete tears of the ATFL, 14 partial tears of the ATFL, 17 CLTs and 7 OSFs. There were no significant differences in the diagnoses of ATFL tears (p = 0.074-0.501), CLT (p = 0.090-0.450) and OSF (p = 0.317) obtained from the 2D and 3D sequences by either reader. The interobserver agreement rates between two readers using the 3D T2-weighted FSE sequence versus those obtained with the 2D sequence were substantial (kappa = 0.659) versus moderate (kappa = 0.553) for ATFL tears, moderate (kappa = 0.499) versus substantial (kappa = 0.676) for CLT and substantial (kappa = 0.621) versus substantial (kappa = 0.689) for OSF. Three-dimensional isotropic T2-weighted FSE MRI of the ankle resulted in no statistically significant difference in diagnostic performance compared to two-dimensional T2-weighted FSE MRI in the evaluation of ATFL tears, CLTs and OSFs.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Internal Medicine > 1. Journal Articles
College of Medicine > Department of Orthopedic Surgery > 1. Journal Articles
College of Medicine > Department of Radiology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Cha, Jang Gyu photo

Cha, Jang Gyu
College of Medicine (Department of Radiology)
Read more

Altmetrics

Total Views & Downloads

BROWSE