Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Diagnostic Ability of Macular Ganglion Cell Layer Measurements in Glaucoma Using Swept Source Optical Coherence Tomography

Authors
Lee, Eung SukChang, Jee HoPark, Tae KwanOhn, Young HoonPark, Ka Hee
Issue Date
Jun-2016
Publisher
대한안과학회
Keywords
Glaucoma; Macular ganglion cell and inner plexiform layer; Macular ganglion cell complex; Swept source optical coherence tomography
Citation
대한안과학회지, v.57, no.6, pp 941 - 950
Pages
10
Journal Title
대한안과학회지
Volume
57
Number
6
Start Page
941
End Page
950
URI
https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/9096
DOI
10.3341/jkos.2016.57.6.941
ISSN
0378-6471
2092-9374
Abstract
Purpose: To evaluate diagnostic ability of macular ganglion cell complex (mGCC), macular ganglion cell inner plexiform layer (mGCIPL) measurements in glaucoma using swept source deep range imaging optical coherence tomography (DRI OCT-1, Topcon Co., Tokyo, Japan). Methods: From August of 2014 to July of 2015, 109 eyes of 109 subjects were assessed for the average thickness and sectional thickness of both mGCC and mGCIPL to determine whether there exists any significant difference among advanced stage glaucoma group, early stage glaucoma group and normal group in Swept source OCT. Comparisons were also made between the above measurements and circumpapillary retinal nerve fiber layer (cpRNFL) thickness measurements in their diagnostic accuracy, sensitivity, and specificity. Results: The diagnostic ability of mGCC based-mean thickness value (area under the curve [AUC] = 0.78/0.99) in detecting early stage glaucoma group as well as advanced stage group was not significantly different from that of cpRNFL thickness measurement. However, there was a significant difference in thickness between mGCIPL (AUC = 0.70) and cpRNFL in early stage glaucoma groups (p = 0.018). The sensitivities and specificities of mGCC were 0.95/0.97, and those of mGCIPL were 0.92/0.97, respectively. Conclusions: The two swept source OCT based methods measuring retinal ganglion cell layer thickness appeared to have a good diagnostic accuracy, high sensitivity and specificity in detecting glaucomatous eyes. Nevertheless, of the two methods, mGCC thickness measurement was more efficient in detecting early glaucomatous changes.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Ophthalmology > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher CHANG, JEE HO photo

CHANG, JEE HO
College of Medicine (Department of Ophthalmology)
Read more

Altmetrics

Total Views & Downloads

BROWSE