Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

환경 바이오모니터링에서의 혈중 중금속 분석 숙련도 시험을 위한 표준물질 제조 및 적용성 평가Development and Validation of Reference Material for Proficiency Testing of Blood Heavy Metals in Environmental Biomonitoring

Other Titles
Development and Validation of Reference Material for Proficiency Testing of Blood Heavy Metals in Environmental Biomonitoring
Authors
임호섭양민호오세림김소영정호준조용민이정섭김현정이채관문찬석이종화
Issue Date
2016
Publisher
한국환경보건학회
Keywords
Biomonitoring; blood cadmium; blood lead; blood mercury; reference materials
Citation
한국환경보건학회지, v.42, no.6, pp 450 - 464
Pages
15
Journal Title
한국환경보건학회지
Volume
42
Number
6
Start Page
450
End Page
464
URI
https://scholarworks.bwise.kr/sch/handle/2021.sw.sch/9523
ISSN
1738-4087
2233-8616
Abstract
Objectives: This study developed and validated reference materials (RMs) to analyze metal compounds in blood. Methods: We referred to KoNEHS (Korea National Environmental Health Survey) to estimate concentrations of blood metals (cadmium, Cd; lead, Pb; mercury, Hg) and applied analytical methods (inductively coupled plasma – mass spectroscopy, ICP-MS, for Cd and Pb; graphite furnace – atomic absorption spectrometry, GFAAS, for Cd and Pb; and direct mercury analyzer, DMA, for Hg). Homogeneity and stability tests were carried out. In addition, certified values and uncertainties of RMs were calculated through internal and external experiments. All RMs were developed and assessed in various forms according to element, analytical method, and two types of concentration levels high concentration for occupational exposure and low concentration for environmental exposure. Results: All samples showed acceptable homogeneity, except for low concentration of Cd in the GF-AAS method. Short- and long-term stabilities were satisfied by ANOVA testing. In the inter-laboratory comparison, robust medians were lower than the certified values of all RMs (robust median/reference value; 1.301/1.327 µg/L for Cd, ICP-MS, low concentration; 3.152/3.388 µg/L for Cd, ICP-MS, high concentration; 1.219/1.301 µg/L for Cd, GF-AAS, low concentration; 3.074/3.321 µg/L for Cd, GF-AAS, high concentration; 14.473/14.516 µg/L for Pb, ICP-MS, low concentration; 50.069/50.114 µg/L for Pb, ICP-MS, high concentration; 12.881/14.147 µg/L for Pb, GF-AAS, low concentration; 47.015/47.591 µg/L for Pb, GF-AAS, high concentration; 4.059/4.218 µg/L for Hg, DMA, low concentration; 11.474/11.181 µg/L for Hg, DMA, high concentration). Conclusion: This study demonstrates procedures for developing and validating RMs for biomonitoring in the field of the environmental health.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Natural Sciences > Department of Environmental Health Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, JONG WHA photo

Lee, JONG WHA
College of Natural Sciences (Department of Environmental Health Science)
Read more

Altmetrics

Total Views & Downloads

BROWSE