Reflection-Boosted Wearable Ring-Type Pulse Oximeters for SpO(2) Measurement with High Sensitivity and Low Power Consumptionopen access

Authors
Joo, MG[Joo, Min Gyu]Lim, DH[Lim, Dae Hyeong]Park, KK[Park, Kyu-Kwan]Baek, J[Baek, Jiwon]Choi, JM[Choi, Jong Min]Baac, HW[Baac, Hyoung Won]
Issue Date
Jul-2023
Publisher
MDPI
Keywords
wearable healthcare device; biophotonics; Monte Carlo simulation; ring-type pulse oximeter; oxygen saturation; photoplethysmography
Citation
BIOSENSORS-BASEL, v.13, no.7
Indexed
SCIE
SCOPUS
Journal Title
BIOSENSORS-BASEL
Volume
13
Number
7
URI
https://scholarworks.bwise.kr/skku/handle/2021.sw.skku/107510
DOI
10.3390/bios13070711
ISSN
2079-6374
Abstract
In this study, we demonstrated a Monte Carlo simulation to model a finger structure and to calculate the intensity of photons passing through tissues, in order to determine optimal angular separation between a photodetector (PD) and a light-emitting diode (LED), to detect SpO(2). Furthermore, our model was used to suggest a mirror-coated ring-type pulse oximeter to improve the sensitivity by up to 80% and improve power consumption by up to 65% compared to the mirror-uncoated structure. A ring-type pulse oximeter (RPO) is widely used to detect photoplethysmography (PPG) signals for SpO(2) measurement during sleep and health-status monitoring. Device sensitivity and the power consumption of an RPO, which are key performance indicators, vary greatly with the geometrical arrangement of PD and LED within the inner surface of an RPO. We propose a reflection-boosted design of an RPO to achieve both high sensitivity and low power consumption, and determine an optimal configuration of a PD and LED by performing a 3D Monte Carlo simulation and confirming its agreement with experimental measurement. In order to confirm the reflection-boosted performance in terms of signal-to-noise ratio, R ratio, and perfusion index (PI), RPOs were fabricated with and without a highly reflective coating, and then used for SpO(2) measurement from eight participants. Our simulation allows the numerical calculation of the intensity of photon passing and scattering through finger tissues. The reflection-boosted RPO enables reliable measurement with high sensitivity, resulting in less power consumption for the LED and longer device usage than conventional RPOs without any reflective coating, in order to maintain the same level of SNR and PI. Compared to the non-reflective reference RPO, the reflection-boosted RPO design greatly enhanced both detected light intensity (67% in dc and 322% in ac signals at a wavelength & lambda;(1) = 660 nm, and also 81% and 375% at & lambda;(2) = 940 nm, respectively) and PI (23.3% at & lambda;(1) and 25.5% at & lambda;(2)). Thus, the reflection-boosted design not only enhanced measurement reliability but also significantly improved power consumption, i.e., by requiring only 36% and 30% power to drive the LED sources with & lambda;(1) and & lambda;(2), respectively, to produce the device performance of a non-reflective RPO reference. It is expected that our proposed RPO provides long-term monitoring capability with low power consumption and an enhanced PI for SpO(2) measurement.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Social Sciences > Media & Communication > 1. Journal Articles
Information and Communication Engineering > School of Electronic and Electrical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher BAAC, HYOUNG WON photo

BAAC, HYOUNG WON
Information and Communication Engineering (Electronic and Electrical Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE