Injectable and tissue-conformable conductive hydrogel for MRI-compatible brain-interfacing electrodes

Authors
Kim, S.D.[Kim, Sung Dong]Park, K.[Park, Kyuha]Lee, S.[Lee, Sungjun]Kum, J.[Kum, Jeungeun]Kim, Y.[Kim, Yewon]An, S.[An, Soojung]Kim, H.[Kim, Hyungmin]Shin, M.[Shin, Mikyung]Son, D.[Son, Donghee]
Issue Date
Jun-2023
Publisher
OAE Publishing Inc.
Keywords
electrocorticogram; electrode array; hyaluronic acid; Injectable conducting hydrogel; MRI; PEDOT:PSS
Citation
Soft Science, v.3, no.2
Indexed
SCOPUS
Journal Title
Soft Science
Volume
3
Number
2
URI
https://scholarworks.bwise.kr/skku/handle/2021.sw.skku/108957
DOI
10.20517/ss.2023.08
ISSN
2769-5441
Abstract
The development of flexible and stretchable materials has led to advances in implantable bio-integrated electronic devices that can sense physiological signals or deliver electrical stimulation to various organs in the human body. Such devices are particularly useful for neural interfacing systems that monitor neurodegenerative diseases such as Parkinson’s disease or epilepsy in real time. However, coupling current brain-interfacing devices with magnetic resonance imaging (MRI) remains a practical challenge due to resonance frequency variations from inorganic metal-based devices. Thus, organic conductive materials, such as poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT:PSS), have recently been considered as promising candidates. Nonetheless, their conformability on curvilinear tissues remains questionable. In this study, we developed an injectable conductive hydrogel (ICH) composed of tyramine-conjugated hyaluronic acid (HATYR) and PEDOT:PSS for MRI-compatible brain-interfacing electrodes. Our ICH produced low impedance around 5 kΩ even under 10 Hz, demonstrating high confidence volumetric capacitance. Due to HATYR’s biocompatibility, histological and cytotoxicity assays showed almost no inflammation and toxicity, respectively; in addition, ICH was able to degrade into 40% of its original volume within four weeks in vivo. An electrocorticogram (ECoG) array was also patternable by syringe injections of ICH on a stretchable and flexible elastomeric substrate layer that conformed to curvy brain tissues and successfully recorded ECoG signals under light stimulation. Furthermore, MRI imaging of implanted devices did not show any artifacts, indicating the potential of the MRI-compatible hydrogel electrodes for advanced ECoG arrays. This study provides a promising solution for MRI-compatible neural electrodes, enabling the advancement of chronic neural interfacing systems for monitoring neurodegenerative diseases. © The Author(s) 2023. Open Access.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Information and Communication Engineering > School of Electronic and Electrical Engineering > 1. Journal Articles
SKKU Institute for Convergence > Biomedical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher SHIN, MIKYUNG photo

SHIN, MIKYUNG
Institute for Cross-disciplinary Studies (ICS) (Biomedical Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE