Effects of modified inertia constant and damping coefficient on power system frequency response

Authors
Zaman, M.S.U.[Zaman, M.S.U.]Bukhari, S.B.A.[Bukhari, S.B.A.]Haider, R.[Haider, R.]Khan, M.O.[Khan, M.O.]Kim, C.-H.[Kim, C.-H.]
Issue Date
2019
Publisher
International Journal of Renewable Energy Research
Keywords
Battery energy storage system (BESS); Demand response (DR); Distributed energy resources (DER); Frequency deviation; Load frequency control (LFC) model; Power system frequency response
Citation
International Journal of Renewable Energy Research, v.9, no.1, pp.525 - 531
Indexed
SCOPUS
Journal Title
International Journal of Renewable Energy Research
Volume
9
Number
1
Start Page
525
End Page
531
URI
https://scholarworks.bwise.kr/skku/handle/2021.sw.skku/14070
ISSN
1309-0127
Abstract
The configuration of modern power system is drastically changing due to integration of distributed energy resources (DER) and responsive loads. Despite their advantages in terms of eco-friendliness and reliability enhancement, DER and responsive loads pose several challenges to the grid's operation and stability. Amongst these challenges are the modification in two critical system parameters: inertia constant ( H ) and damping coefficient ( D ). Typically, these parameters are considered unchanged during the operation of a power system. However, the high penetration of responsive loads and BESS may alter their values from the calculated or presumed values. In this work, an analysis of power system frequency response is presented considering the modifications in these two parameters. After explaining how DER and responsive loads modify these parameters, it is demonstrated that a mismatch between actual and presumed values of these parameters may degrade the reliability and economy of the power system. The study considers two typical configurations (i.e., with and without automatic generation control) of the power system, and highlights the importance of accurate calculation of H and D when DER and responsive loads have significant shares. © 2019, International Journal of Renewable Energy Research.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Information and Communication Engineering > School of Electronic and Electrical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher KIM, CHUL HWAN photo

KIM, CHUL HWAN
Information and Communication Engineering (Electronic and Electrical Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE