Detailed Information

Cited 27 time in webofscience Cited 30 time in scopus
Metadata Downloads

Measurement of lens density using Scheimpflug imaging system as a screening test in the field of health examination for age-related cataract

Authors
Lim, DH[Lim, Dong Hui]Kim, TH[Kim, Tae Hyup]Chung, ES[Chung, Eui-Sang]Chung, TY[Chung, Tae-Young]
Issue Date
Feb-2015
Publisher
BMJ PUBLISHING GROUP
Citation
BRITISH JOURNAL OF OPHTHALMOLOGY, v.99, no.2, pp.184 - 191
Indexed
SCIE
SCOPUS
Journal Title
BRITISH JOURNAL OF OPHTHALMOLOGY
Volume
99
Number
2
Start Page
184
End Page
191
URI
https://scholarworks.bwise.kr/skku/handle/2021.sw.skku/44740
DOI
10.1136/bjophthalmol-2014-305632
ISSN
0007-1161
Abstract
Purpose To assess Pentacam (Oculus, Wetzlar, Germany) Scheimpflug quantitative images in evaluating lens density and providing objective measurements to suggest optimal time of cataract surgery in the field of health examination. Methods Two hundred and twenty-nine eyes with age-related cataract were enrolled. Lens density was measured using Pentacam. All Pentacam images were exported to ImageJ (NIH, Bethesda, Maryland, USA) for quantitative analysis. Average lens density (ALD) and nuclear lens density (NLD) were calculated. Lens density was also evaluated by built-in Pentacam Nucleus Staging (PNS) software. Slit-lamp microscopy was performed for cataract grading according to Lens Opacification Classification System III (LOCS III). The best-corrected visual acuity (BCVA) was measured. All measurements were compared between the cataract surgery and non-cataract surgery groups. Results The measurements of Pentacam images significantly correlated with LOCS III for nuclear opalescence (NO) and nuclear colour (NC) grading (p<0.01). Pentacam ImageJ showed higher correlation than PNS. The mean NLD was most highly correlated with NO (r=0.8833) and NC (r=0.6815). The maximum ALD was most highly correlated with cortical opacity (r=0.5381). All Pentacam measurements of lens density and BCVA were significantly different between the cataract surgery and non-surgery groups (p<0.01). The optimised cut-off values to perform cataract surgery for mean NLD and maximum ALD were 26 and 74, respectively (p<0.01). Conclusions The Pentacam ImageJ method provided objective measurements to evaluate cataracts needing surgery. The method has the potential to be generally applied in the field of health examination and is effective in screening patients with cataract.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Medicine > Department of Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE