Occupational radiation exposure in femoral artery approach is higher than radial artery approach during coronary angiography or percutaneous coronary intervention

Authors
Kim, JS[Kim, Jung-Su]Lee, BK[Lee, Bong-Ki]Ryu, DR[Ryu, Dong-Ryeol]Chun, K[Chun, Kwangjin]Kwon, HS[Kwon, Ho-Seok]Nam, SR[Nam, So-Ra]Kim, DI[Kim, Doo-il]Lee, SY[Lee, Sung-Yun]Jeong, JO[Jeong, Jin-Ok]Bae, JW[Bae, Jang-Whan]Park, JS[Park, Jong-Seon]Ahn, Y[Ahn, Youngkeun]Chae, JK[Chae, Je-Keon]Yoon, MH[Yoon, Myeong-Ho]Lee, SH[Lee, Seung-Hwan]Yoon, J[Yoon, Jeonghan]Gwon, HC[Gwon, Hyeon-Cheol]Choi, D[Choi, Donghoon]Kwon, SM[Kwon, Soon-Mu]Roh, YH[Roh, Young-Hoon]Cho, BR[Cho, Byung-Ryul]
Issue Date
28-Apr-2020
Publisher
NATURE PUBLISHING GROUP
Citation
SCIENTIFIC REPORTS, v.10, no.1
Indexed
SCIE
SCOPUS
Journal Title
SCIENTIFIC REPORTS
Volume
10
Number
1
URI
https://scholarworks.bwise.kr/skku/handle/2021.sw.skku/4836
DOI
10.1038/s41598-020-62794-2
ISSN
2045-2322
Abstract
Medical radiation exposure is a significant concern for interventional cardiologists (IC). This study was aimed at estimating the radiation exposure of IC operators and assistants in real clinical practice. The radiation exposure of the operator and assistant was evaluated by conducting two types of procedures via coronary angiography (CAG) and percutaneous coronary intervention (PCI) on 1090 patients in 11-cardiovascular centers in Korea. Radiation exposure was measured using an electronic personal dosimeter (EPD). EPD were attached at 3 points on each participant: on the apron on the left anterior chest (A1), under the apron on the sternum (A2), and on the thyroid shield (T). Average radiation exposure (ARE) of operators at A1, A2, and T was 19.219 uSv, 4.398 uSv, and 16.949 uSv during CAG and 68.618 uSv, 15.213 uSv, and 51.197 uSv during PCI, respectively. ARE of assistants at A1, A2, and T was 4.941 uSv, 0.860 uSv, and 5.232 uSv during CAG and 20.517 uSv, 4.455 uSv, and 16.109 uSv during PCI, respectively. AED of operator was 3.4 times greater during PCI than during CAG.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Medicine > Department of Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher GWON, HYEON CHEOL photo

GWON, HYEON CHEOL
Medicine (Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE