Detailed Information

Cited 8 time in webofscience Cited 7 time in scopus
Metadata Downloads

Simultaneous evaluation of vascular morphology, blood volume and transvascular permeability using SPION-based, dual-contrast MRI: Imaging optimization and feasibility test

Authors
Kwon H.-J.[Kwon H.-J.]Shim W.H.[Shim W.H.]Cho G.[Cho G.]Cho H.J.[Cho H.J.]Jung H.S.[Jung H.S.]Lee C.K.[Lee C.K.]Lee Y.S.[Lee Y.S.]Baek J.H.[Baek J.H.]Kim E.J.[Kim E.J.]Suh J.-Y.[Suh J.-Y.]Sung Y.S.[Sung Y.S.]Woo D.-C.[Woo D.-C.]Kim Y.R.[Kim Y.R.]Kim J.K.[Kim J.K.]
Issue Date
2015
Keywords
dual contrast; superparamagnetic iron oxide nanoparticles; ultrashort T-E imaging; water exchange index; blood volume; MR angiography
Citation
NMR in Biomedicine, v.28, no.6, pp.624 - 632
Journal Title
NMR in Biomedicine
Volume
28
Number
6
Start Page
624
End Page
632
URI
https://scholarworks.bwise.kr/skku/handle/2021.sw.skku/49156
DOI
10.1002/nbm.3293
Abstract
Exploiting ultrashort-T<inf>E</inf> (UTE) MRI, T<inf>1</inf>-weighted positive contrast can be obtained from superparamagnetic iron oxide nanoparticles (SPIONs), which are widely used as a robust T<inf>2</inf>-weighted, negative contrast agent on conventional MR images. Our study was designed (a) to optimize the dual-contrast MRI method using SPIONs and (b) to validate the feasibility of simultaneously evaluating the vascular morphology, blood volume and transvascular permeability using the dual-contrast effect of SPIONs. All studies were conducted using 3T MRI. According to numerical simulation, 0.15mM was the optimal blood SPION concentration for visualizing the positive contrast effect using UTE MRI (T<inf>E</inf>=0.09ms), and a flip angle of 40° could provide sufficient SPION-induced enhancement and acceptable measurement noise for UTE MR angiography. A pharmacokinetic study showed that this concentration can be steadily maintained from 30 to 360min after the injection of 29mg/kg of SPIONs. An in vivo study using these settings displayed image quality and CNR of SPION-enhanced UTE MR angiography (image quality score 3.5; CNR 146) comparable to those of the conventional, Gd-enhanced method (image quality score 3.8; CNR 148) (p>0.05). Using dual-contrast MR images obtained from SPION-enhanced UTE and conventional spin- and gradient-echo methods, the transvascular permeability (water exchange index 1.76-1.77), cerebral blood volume (2.58-2.60%) and vessel caliber index (3.06-3.10) could be consistently quantified (coefficient of variation less than 9.6%; Bland-Altman 95% limits of agreement 0.886-1.111) and were similar to the literature values. Therefore, using the optimized setting of combined SPION-based MRI techniques, the vascular morphology, blood volume and transvascular permeability can be comprehensively evaluated during a single session of MR examination. © 2015 John Wiley & Sons, Ltd.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Medicine > Department of Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher KWON, HEON JU photo

KWON, HEON JU
Medicine (Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE