Performance Improvement of Isolated High Voltage Full Bridge Converter Using Voltage Doubler

Authors
Lee, HJ[Lee, Hee-Jun]Shin, SC[Shin, Soo-Cheol]Hong, SJ[Hong, Seok-Jin]Hyun, SW[Hyun, Seung-Wook]Lee, JH[Lee, Jung-Hyo]Won, CY[Won, Chung-Yuen]
Issue Date
Nov-2014
Citation
JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, v.9, no.6, pp.2224 - 2236
Indexed
SCIE
SCOPUS
KCI
Journal Title
JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY
Volume
9
Number
6
Start Page
2224
End Page
2236
URI
https://scholarworks.bwise.kr/skku/handle/2021.sw.skku/50960
DOI
10.5370/JEET.2014.9.6.2224
ISSN
1975-0102
Abstract
The performance of an isolated high voltage full bridge converter is improved using a voltage doubler. In a conventional high voltage full bridge converter, the diode of the transformer secondary voltage undergoes a voltage spike due to the leakage inductance of the transformer and the resonance occurring with the parasitic capacitance of the diode. In addition, in the phase shift control, conduction loss largely increases from the freewheeling mode because of the circulating current. The efficiency of the converter is thus reduced. However, in the proposed converter, the high voltage dual converter consists of a voltage doubler because the circulating current of the converter is reduced to increase efficiency. On the other hand, in the proposed converter, an input current is distributed when using parallel input / serial output and the output voltage can be doubled. However, the voltages in the 2 serial DC links might be unbalanced due to line impedance, passive and active components impedance, and sensor error. Considering these problems, DC injection is performed due to the complementary operations of half bridge inverters as well as the disadvantage of the unbalance in the DC link. Therefore, the serial output of the converter needs to control the balance of the algorithm. In this paper, the performance of the conventional converter is improved and a balance control algorithm is proposed for the proposed converter. Also, the system of the 1.5[kW] PCS is verified through an experiment examining the operation and stability.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Information and Communication Engineering > School of Electronic and Electrical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE