Detailed Information

Cited 5 time in webofscience Cited 6 time in scopus
Metadata Downloads

Development of Equipment and Application of Machine Learning Techniques Using Frequency Response Data for Cap Damage Detection of Porcelain Insulators

Authors
Choi, IH[Choi, In Hyuk]Koo, JB[Koo, Ja Bin]Son, JA[Son, Ju Am]Yi, JS[Yi, Jun Sin]Yoon, YG[Yoon, Young Geun]Oh, TK[Oh, Tae Keun]
Issue Date
Feb-2020
Publisher
MDPI
Keywords
frequency response function; porcelain insulator; cap; auto impact hammer; MEMS; non-destructive method; damage detection; machine learning
Citation
APPLIED SCIENCES-BASEL, v.10, no.8
Indexed
SCIE
SCOPUS
Journal Title
APPLIED SCIENCES-BASEL
Volume
10
Number
8
URI
https://scholarworks.bwise.kr/skku/handle/2021.sw.skku/5698
DOI
10.3390/app10082820
ISSN
2076-3417
Abstract
The most common method for inspection of insulators is to measure the change of electrical characteristics such as electric resistance and partial discharge. However, even if there is no physical damage, these values vary depending on the temperature, humidity, and chloride content of the atmosphere. In this respect, an alternative to such methods can be the impact response test, and a frequency response function (FRF) obtained from the test has been widely used as a tool for damage detection. In this study the FRF was applied to identify the cap damage of porcelain insulators. In addition, to solve the danger of high voltage and poor field accessibility near the insulator, a device with high field applicability was developed to measure FRF from a long distance using an auto impact hammer and Micro Electro Mechanical Systems (MEMS) technology. Even though the FRF is most suitable for inspection of porcelain insulators, dynamic characteristics such as natural frequencies may vary depending on manufacturing errors, installation conditions, etc., which may cause difficulties in damage identification. To overcome this limitation, the machine learning (ML) method was applied in this study to provide a diagnostic method that ensured consistent and accurate judgment. As a result of predicting the normal and the cap damage data using the support vector machine (SVM), bagging, k-nearest neighbor (kNN), and discriminant analysis (DA) methods, the overall F1 score was over 87% and the bagging method achieved the highest accuracy. In this study, the frequency range and dynamic characteristics that are sensitive to the physical damage of the insulator were derived and, based on this, the optimum ML methods with improved equipment could provide analysis with higher accuracy and consistency than general analysis using the FRF.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Information and Communication Engineering > School of Electronic and Electrical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher YI, JUN SIN photo

YI, JUN SIN
Information and Communication Engineering (Electronic and Electrical Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE