Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

In Vivo Comparison of MONOFIX, A Novel Barbed Suture with a Triangular Stopper, with Pre-existing Products in a Porcine Model

Authors
Kim, J[Kim, Jihye]Eom, HJ[Eom, Hye Jin]Shin, H[Shin, Hyeongchan]Jeong, SY[Jeong, Soo Young]Kim, MS[Kim, Myeong Seon]Yoon, HS[Yoon, Hye Sung]In, CH[In, Chang Hoon]Kim, BG[Kim, Byoung-Gie]Bae, DS[Bae, Duk-Soo]Lee, JW[Lee, Jeong-Won]
Issue Date
Feb-2020
Publisher
ELSEVIER SCIENCE INC
Keywords
Barbed suture; Biomechanics; Histology; In vivo; Laparoscopic surgery
Citation
JOURNAL OF MINIMALLY INVASIVE GYNECOLOGY, v.27, no.2, pp.473 - 481
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF MINIMALLY INVASIVE GYNECOLOGY
Volume
27
Number
2
Start Page
473
End Page
481
URI
https://scholarworks.bwise.kr/skku/handle/2021.sw.skku/5809
DOI
10.1016/j.jmig.2019.04.005
ISSN
1553-4650
Abstract
Study Objective: MONOFIX, a new absorbable barbed suture device, has a triangular stopper at the end to hold the suture to the tissue without hooking the looped end or knotting. The aim of this study was to compare the biomechanical strength and histologic features of MONOFIX with other barbed suture devices using a porcine model. Design: Well-designed, controlled trial without randomization. Setting: Animal laboratory in university hospital. Subjects: Sixteen, 60-kg, mature female domestic pigs (skin closure group) and 5, 60-kg, mature female domestic pigs (fascial closure group). Interventions: In the skin closure group, 3-0 MONOFIX versus 2 widely used 3-0 absorbable barbed sutures (3-0 V-Loc 180 or Stratafix). In the fascial closure group, 2-0 MONOFIX versus 1 widely used 2-0 absorbable barbed sutures (2-0 Stratafix). Measurements and Main Results: In the skin closure group, the biomechanical wound strength of skin sutured with size 3-0 MONOFIX, V-Loc 180, or Stratafix was evaluated by postoperative day assessment (days 0, 3, 7, 14, and 28). In the fascial closure group, pigs underwent 2 paramedian incisions and were sutured with 2-0 MONOFIX or with 2-0 Stratafix to evaluate histologic reaction. At 6 weeks the tissues around the suture line were excised and microscopically evaluated. The biomechanical strength of the MONOFIX had similar tissue tensile strength compared with the control, regardless of postoperative day. In the fascial closure model, there was no significant difference in the average tissue reaction score between MONOFIX and Stratafix (1.2 +/- .3 vs 1.3 +/- .3, p = .478). Conclusion: This study demonstrated that MONOFIX has equivalent tensile strength and histologic reaction when compared with commonly used barbed suture devices. Accordingly, this preclinical study suggests that the use of MONOFIX is a safe alternative to other barbed suture devices. (C) 2019 Published by Elsevier Inc. on behalf of AAGL.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Medicine > Department of Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher KIM, JI HYE photo

KIM, JI HYE
Medicine (Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE