Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

TU‐FF‐A4‐01: Virtual Simulator Design for Collision Prevention During External Radiotherapy Planning

Authors
Kum, O.[Kum, O.]Kim, S.[ Kim, S.]Han, Y.[Han, Y.]
Issue Date
2008
Citation
Medical Physics, v.35, no.6, pp.2923
Indexed
SCOPUS
Journal Title
Medical Physics
Volume
35
Number
6
Start Page
2923
URI
https://scholarworks.bwise.kr/skku/handle/2021.sw.skku/82339
DOI
10.1118/1.2962656
ISSN
0094-2405
Abstract
Purpose: Collision avoidance of the treatment accelerator components such as gantry, table, collimators, jaws, and fixation devices with the patient is one of the biggest concerns in external treatment planning. Most commercial treatment planning systems do not include collision prevention simulation step. On the other hand, a fool‐proof collision‐map, lookup table, and simpler analytical method guard only against the most apparent collisions. Thus, a comprehensive virtual simulator design for collision avoidance is very useful for external radiotherapy planning. Method and Materials: An accurate modeling of the treatment accelerator is possible with geometric data. Three‐dimensional patient modeling is also possible from the patient's CT data. Since each component in the data bank is described as an independent mesh modeling based on the type of associated polygons, relative position changes can be described easily for the device dynamics simulation. The relative motions of the gantry and the treatment table are collected from the treatment plan and the graphical user interface generates the events at the given time intervals. This visual system is incorporated with the treatment planning simulation system. Results: The quality verification of our virtual simulator for the potential collision has been performed with two combinations of treatment table and gantry rotations where a collision is eminent based on the visual assessment. The planner can search for beam paths with minimal critical structure interference before extensive optimization process. A database of CT and MR scans for all tumor sites is being built, which provide useful information to map all potential collision possibilities for all treatment isocenters. Conclusion: The important benefits of this virtual simulator is the replacement of the conventional laborious procedures required for the expensive hardware simulator unit, the efficiency increment, the accuracy improvement of radiation treatment procedure, and the cost reduction in terms of time and physical patient's presence. © 2008, American Association of Physicists in Medicine. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Medicine > Department of Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher HAN, YOUNG YIH photo

HAN, YOUNG YIH
Medicine (Medicine)
Read more

Altmetrics

Total Views & Downloads

BROWSE