Detailed Information

Cited 9 time in webofscience Cited 10 time in scopus
Metadata Downloads

Automated stitching of microscope images of fluorescence in cells with minimal overlap

Authors
Seo, J.-H.[Seo, J.-H.]Yang, S.[Yang, S.]Kang, M.-S.[Kang, M.-S.]Her, N.-G.[Her, N.-G.]Nam, D.-H.[Nam, D.-H.]Choi, J.-H.[Choi, J.-H.]Kim, M.H.[Kim, M.H.]
Issue Date
Nov-2019
Publisher
PERGAMON-ELSEVIER SCIENCE LTD
Keywords
Brain tumor cell; Fluorescence microscope images; High-content screening; Image stitching; Tile scan
Citation
MICRON, v.126
Indexed
SCIE
SCOPUS
Journal Title
MICRON
Volume
126
URI
https://scholarworks.bwise.kr/skku/handle/2021.sw.skku/8339
DOI
10.1016/j.micron.2019.102718
ISSN
0968-4328
Abstract
The morphology of tumor cells is highly related to their phenotype and activity. To verify the drug response of a brain tumor patient, fluorescence microscope images of drug-treated patient-derived cells in each well are analyzed. Due to the limitation of the field of view (FOV), a large number of small FOVs are acquired to compose one complete microscope well. Here, we propose an automated method for accurately stitching tile-scanned fluorescence microscope images, even with noise and a narrow overlapping region between adjacent fields. The proposed method is based on intensity-based normalized cross-correlation (NCC) and a triangular method-based threshold. The proposed method's quantitative accuracy and the sensitivity of the input was compared to other existing stitching tools, MIST and FijiIS, setting manually stitched images as the ground truth. The test images were 20 samples of 3 x 3 grid images in three versions of the fluorescence channel. The distance between the location of each field and number of cells was determined for different input field overlap ranges (1%, 3%, 5%, and 10%), while the actual value was about 1.15%. The proposed method had a distance error of 1.5 pixels at an input overlap of 1%, showing the lowest minimum error at all channels. Regarding the difference in cell numbers, although the number of overlapping cells was always small because of the narrow overlapping range, the proposed method was able to generate the resultant image with the smallest difference. In addition, to confirm the size limitation of the proposed algorithm, the accuracy of stitching images of grid structures 3 x 3, 5 x 5, 10 x 10-20 x 20 was tested, showing consistent results: In conclusion, quantitative evaluation of the performance of the method proved its improved accuracy compared to other current state-of-art techniques, and it showed robust performance even with noise and a narrow overlapping region between adjacent fields.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Medicine > Department of Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.