Detailed Information

Cited 1 time in webofscience Cited 2 time in scopus
Metadata Downloads

Improvement of megavoltage computed tomography image quality for adaptive helical tomotherapy using cycleGAN-based image synthesis with small datasets

Authors
Lee, D.[Lee, D.]Jeong, S.W.[Jeong, S.W.]Kim, S.J.[Kim, S.J.]Cho, H.[Cho, H.]Park, W.[Park, W.]Han, Y.[Han, Y.]
Issue Date
Oct-2021
Publisher
John Wiley and Sons Ltd
Keywords
adaptive radiation therapy; cycleGAN; data augmentation; deep learning; image synthesis; megavoltage computed tomography
Citation
Medical Physics, v.48, no.10, pp.5593 - 5610
Indexed
SCIE
SCOPUS
Journal Title
Medical Physics
Volume
48
Number
10
Start Page
5593
End Page
5610
URI
https://scholarworks.bwise.kr/skku/handle/2021.sw.skku/91049
DOI
10.1002/mp.15182
ISSN
0094-2405
Abstract
Purpose: Megavoltage computed tomography (MVCT) offers an opportunity for adaptive helical tomotherapy. However, high noise and reduced contrast in the MVCT images due to a decrease in the imaging dose to patients limits its usability. Therefore, we propose an algorithm to improve the image quality of MVCT. Methods: The proposed algorithm generates kilovoltage CT (kVCT)-like images from MVCT images using a cycle-consistency generative adversarial network (cycleGAN)-based image synthesis model. Data augmentation using an affine transformation was applied to the training data to overcome the lack of data diversity in the network training. The mean absolute error (MAE), root-mean-square error (RMSE), peak signal-to-noise ratio (PSNR), and structural similarity index measure (SSIM) were used to quantify the correction accuracy of the images generated by the proposed algorithm. The proposed method was validated by comparing the images generated with those obtained from conventional and deep learning-based image processing method through non-augmented datasets. Results: The average MAE, RMSE, PSNR, and SSIM values were 18.91 HU, 69.35 HU, 32.73 dB, and 95.48 using the proposed method, respectively, whereas cycleGAN with non-augmented data showed inferior results (19.88 HU, 70.55 HU, 32.62 dB, 95.19, respectively). The voxel values of the image obtained by the proposed method also indicated similar distributions to those of the kVCT image. The dose-volume histogram of the proposed method was also similar to that of electron density corrected MVCT. Conclusions: The proposed algorithm generates synthetic kVCT images from MVCT images using cycleGAN with small patient datasets. The image quality achieved by the proposed method was correspondingly improved to the level of a kVCT image while maintaining the anatomical structure of an MVCT image. The evaluation of dosimetric effectiveness of the proposed method indicates the applicability of accurate treatment planning in adaptive radiation therapy. © 2021 American Association of Physicists in Medicine
Files in This Item
There are no files associated with this item.
Appears in
Collections
Medicine > Department of Medicine > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher HAN, YOUNG YIH photo

HAN, YOUNG YIH
Medicine (Medicine)
Read more

Altmetrics

Total Views & Downloads