아날로그 회로로 구현가능한 평균전류제어 저손실 bypass 전류센싱방법
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김석희 | - |
dc.contributor.author | 최병민 | - |
dc.contributor.author | 박종후 | - |
dc.contributor.author | 전희종 | - |
dc.date.available | 2018-05-09T12:00:53Z | - |
dc.date.created | 2018-04-17 | - |
dc.date.issued | 2014-04 | - |
dc.identifier.issn | 1229-2214 | - |
dc.identifier.uri | http://scholarworks.bwise.kr/ssu/handle/2018.sw.ssu/10484 | - |
dc.description.abstract | This paper proposes a low power-loss averaging current mode control using a resistor and bypass switch. Generally, current sensing method using a resistor has a disadvantage of power loss which degrades the efficiency of the entire systems. On the other hand, proposed measurement technique operating with bypass-switch connected in parallel with sensing resistor can reduce power loss significantly the current sensor. An analog-circuited bypass driver is implemented and used along with an average-circuit mode controller. The bypass switch bypasses the sensing current with a small amount of power loss. In this paper, a 50[W] prototype average current mode boost converter has been implemented for the experimental verification. | - |
dc.language | 한국어 | - |
dc.language.iso | ko | - |
dc.publisher | 전력전자학회 | - |
dc.relation.isPartOf | 전력전자학회 논문지 | - |
dc.subject | shunt resistor | - |
dc.subject | current measurement | - |
dc.subject | averaging current mode control | - |
dc.subject | current sampling | - |
dc.subject | bypass switch | - |
dc.subject | high efficiency | - |
dc.subject | sample-and-holder | - |
dc.title | 아날로그 회로로 구현가능한 평균전류제어 저손실 bypass 전류센싱방법 | - |
dc.title.alternative | The Analog-circuited Low-loss Bypass Current Sensing Method for Average Current Mode Control | - |
dc.type | Article | - |
dc.identifier.doi | 10.6113/TKPE.2014.19.2.133 | - |
dc.type.rims | ART | - |
dc.identifier.bibliographicCitation | 전력전자학회 논문지, v.19, no.2, pp.133 - 138 | - |
dc.identifier.kciid | ART001868125 | - |
dc.description.journalClass | 2 | - |
dc.citation.endPage | 138 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 133 | - |
dc.citation.title | 전력전자학회 논문지 | - |
dc.citation.volume | 19 | - |
dc.contributor.affiliatedAuthor | 박종후 | - |
dc.contributor.affiliatedAuthor | 전희종 | - |
dc.identifier.url | https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART001868125 | - |
dc.description.isOpenAccess | N | - |
dc.description.oadoiVersion | published | - |
dc.subject.keywordAuthor | shunt resistor | - |
dc.subject.keywordAuthor | current measurement | - |
dc.subject.keywordAuthor | averaging current mode control | - |
dc.subject.keywordAuthor | current sampling | - |
dc.subject.keywordAuthor | bypass switch | - |
dc.subject.keywordAuthor | high efficiency | - |
dc.subject.keywordAuthor | sample-and-holder | - |
dc.description.journalRegisteredClass | kci | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Soongsil University Library 369 Sangdo-Ro, Dongjak-Gu, Seoul, Korea (06978)02-820-0733
COPYRIGHT ⓒ SOONGSIL UNIVERSITY, ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.