FEASIBILITY OF ICE-SLURRY APPLICATION TO THE DISTRICT COOLING SYSTEM IN KOREA
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 정재동 | - |
dc.contributor.author | 문승재 | - |
dc.contributor.author | 이윤표 | - |
dc.contributor.author | 이재헌 | - |
dc.contributor.author | 이창준 | - |
dc.contributor.author | 유호선 | - |
dc.date.available | 2018-05-09T12:01:48Z | - |
dc.date.created | 2018-04-17 | - |
dc.date.issued | 2014 | - |
dc.identifier.issn | 2010-1325 | - |
dc.identifier.uri | http://scholarworks.bwise.kr/ssu/handle/2018.sw.ssu/10512 | - |
dc.description.abstract | The district-cooling system (DCS) has been in service in Sang-am in Seoul, Korea since 2005. The capacity of the DCS facility in Sang-am was 111 Gcal/h in 2011, and an additional 63 Gcal/h capacity is planned for installation by 2025. However, the cooling demand has increased due to unexpected high-rise building blocks, and the required facility capacity is expected to be 101 Gcal/h. Adding a new building plan to the existing plant is difficult. This study centers on a feasibility study for the new requirement under the restrictions of existing pipelines, limited space and regulations on the use of electric-driven chillers in Korea, etc. The precise estimation of the diversity factor is essential to determine the required capacities. To this end, each building in the district area was categorized, and the cooling loads were measured for the summer seasons of 2010 and 2011. The large energy capacity of an ice-slurry can potentially increase the cooling capacity in existing plants while maintaining the same flow rate and pumping power. Thus introducing an ice-slurry is expected to be a potential solution to the significantly increased cooling load under the restriction of existing pipeline system without requiring increases in pipe size or system flow rates. | - |
dc.publisher | 대한설비공학회 | - |
dc.relation.isPartOf | International Journal of Air-Conditioning and Refrigeration | - |
dc.subject | Ice-slurry | - |
dc.subject | district-cooling system | - |
dc.subject | feasibility | - |
dc.subject | diversity factor | - |
dc.subject | cooling load | - |
dc.title | FEASIBILITY OF ICE-SLURRY APPLICATION TO THE DISTRICT COOLING SYSTEM IN KOREA | - |
dc.type | Article | - |
dc.identifier.doi | 10.1142/S2010132514500187 | - |
dc.type.rims | ART | - |
dc.identifier.bibliographicCitation | International Journal of Air-Conditioning and Refrigeration, v.22, no.3, pp.1 - 10 | - |
dc.identifier.kciid | ART001913256 | - |
dc.description.journalClass | 2 | - |
dc.citation.endPage | 10 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 1 | - |
dc.citation.title | International Journal of Air-Conditioning and Refrigeration | - |
dc.citation.volume | 22 | - |
dc.contributor.affiliatedAuthor | 유호선 | - |
dc.subject.keywordAuthor | Ice-slurry | - |
dc.subject.keywordAuthor | district-cooling system | - |
dc.subject.keywordAuthor | feasibility | - |
dc.subject.keywordAuthor | diversity factor | - |
dc.subject.keywordAuthor | cooling load | - |
dc.description.journalRegisteredClass | other | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Soongsil University Library 369 Sangdo-Ro, Dongjak-Gu, Seoul, Korea (06978)02-820-0733
COPYRIGHT ⓒ SOONGSIL UNIVERSITY, ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.