Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

단상 하프-브리지 부스트 컨버터에서 DC 전해 커패시터의 고장예측 모니터링

Authors
서장수손진근전희종
Issue Date
2014
Publisher
대한전기학회
Keywords
Electrolytic capacitor; ESR(equivalent series resistance); Failure prediction monitoring; Half-bridge boost converter; PFC(power factor correction)
Citation
전기학회 논문지 P권, v.63, no.4, pp.345 - 350
Journal Title
전기학회 논문지 P권
Volume
63
Number
4
Start Page
345
End Page
350
URI
http://scholarworks.bwise.kr/ssu/handle/2018.sw.ssu/10635
ISSN
1229-800x
Abstract
DC electrolytic capacitor is widely used in the power converter including PWM inverter, switching powersupply and PFC Boost converter system because of its large capacitance, small size and low cost. In this paper, basiccharacteristics of DC electrolytic capacitor vs. frequency is presented and the real-time estimation scheme of ESR andcapacitance based on the bandpass filtering is adopted to the single phase boost converter of uninterruptible powersupply to diagnose its split dc-link capacitors. The feasibility of this real-time failure prediction monitoring system isverified by the computer simulation of the 5[kW] singe phase PFC half-bridge boost converter.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Electrical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jeon, Hee Jong photo

Jeon, Hee Jong
공과대학 (전기공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE