Detailed Information

Cited 16 time in webofscience Cited 19 time in scopus
Metadata Downloads

Simultaneous measurements of pure scintillation and Cerenkov signals in an integrated fiber-optic dosimeter for electron beam therapy dosimetry

Full metadata record
DC Field Value Language
dc.contributor.authorYoo, Wook Jae-
dc.contributor.authorShin, Sang Hun-
dc.contributor.authorJeon, Dayeong-
dc.contributor.authorHong, Seunghan-
dc.contributor.authorKim, Seon Geun-
dc.contributor.authorSim, Hyeok In-
dc.contributor.authorJang, Kyoung Won-
dc.contributor.authorCho, Seunghyun-
dc.contributor.authorLee, Bongsoo-
dc.date.available2018-05-09T13:55:23Z-
dc.date.created2018-04-17-
dc.date.issued2013-11-18-
dc.identifier.issn1094-4087-
dc.identifier.urihttp://scholarworks.bwise.kr/ssu/handle/2018.sw.ssu/11108-
dc.description.abstractFor real-time dosimetry in electron beam therapy, an integrated fiber-optic dosimeter (FOD) is developed using a water-equivalent dosimeter probe, four transmitting optical fibers, and a multichannel light-measuring device. The dosimeter probe is composed of two inner sensors, a scintillation sensor and a Cerenkov sensor, and each sensor has two different channels. Accordingly, we measured four separate light signals from each channel in the dosimeter probe, simultaneously, and then obtained the scintillation and Cerenkov signals using a subtraction method. To evaluate the performance of the integrated FOD, we measured the light signals according to the irradiation angle of the electron beam, the depth variation of the solid water phantom, and the electron beam energy. In conclusion, we demonstrated that the pure scintillation and Cerenkov signals obtained by an integrated FOD system based on a subtraction method can be effectively used for calibrating the conditions of high-energy electron beams in radiotherapy. (C) 2013 Optical Society of America-
dc.publisherOPTICAL SOC AMER-
dc.relation.isPartOfOPTICS EXPRESS-
dc.subjectRADIATION SENSOR-
dc.subjectOPTICAL-FIBERS-
dc.subjectRADIOTHERAPY-
dc.subjectLIGHT-
dc.subjectARRAY-
dc.subjectDETECTOR-
dc.titleSimultaneous measurements of pure scintillation and Cerenkov signals in an integrated fiber-optic dosimeter for electron beam therapy dosimetry-
dc.typeArticle-
dc.identifier.doi10.1364/OE.21.027770-
dc.type.rimsART-
dc.identifier.bibliographicCitationOPTICS EXPRESS, v.21, no.23, pp.27770 - 27779-
dc.description.journalClass1-
dc.identifier.wosid000327494000022-
dc.identifier.scopusid2-s2.0-84888270567-
dc.citation.endPage27779-
dc.citation.number23-
dc.citation.startPage27770-
dc.citation.titleOPTICS EXPRESS-
dc.citation.volume21-
dc.contributor.affiliatedAuthorCho, Seunghyun-
dc.type.docTypeArticle-
dc.subject.keywordPlusRADIATION SENSOR-
dc.subject.keywordPlusOPTICAL-FIBERS-
dc.subject.keywordPlusRADIOTHERAPY-
dc.subject.keywordPlusLIGHT-
dc.subject.keywordPlusARRAY-
dc.subject.keywordPlusDETECTOR-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Organic Materials and Fiber Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Cho, Seung hyun photo

Cho, Seung hyun
College of Engineering (Department of Materials Science and Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE