Thermal Performance Evaluation of Curtain Wall Frame Types
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Song, Yong Woo | - |
dc.contributor.author | Park, Jin Chul | - |
dc.contributor.author | Chung, Min Hee | - |
dc.contributor.author | Choi, Byung Do | - |
dc.contributor.author | Park, Jung Ha | - |
dc.date.available | 2018-05-09T14:12:14Z | - |
dc.date.created | 2018-04-17 | - |
dc.date.issued | 2013-05 | - |
dc.identifier.issn | 1346-7581 | - |
dc.identifier.uri | http://scholarworks.bwise.kr/ssu/handle/2018.sw.ssu/11286 | - |
dc.description.abstract | This study is an evaluation of thermal performance according to curtain wall frame types. Heat transfer simulations were conducted on the currently preferred aluminum, steel and scagliola frames, which improved thermal performance and actual frames were produced for thermal performance experiments. The results of this study can be summarized as follows: when heat transfer simulation was conducted to compare the thermal performance of the three frames for summer and winter, scagliola showed the lowest temperature difference, both inside and outside with excellent thermal performance compared to the aluminum/steel frame. Also, as a result of a mock-up test based on the simulation results, for both night and day, the temperature difference was found to be lowest for the scagliola frame. Therefore, it was found that by applying the scagliola frame which improves on the thermal performance of the aluminum/steel frame, the heat loss from frames can be reduced. | - |
dc.publisher | ARCHITECTURAL INST JAPAN | - |
dc.relation.isPartOf | JOURNAL OF ASIAN ARCHITECTURE AND BUILDING ENGINEERING | - |
dc.subject | BUILDING ENVELOPE | - |
dc.title | Thermal Performance Evaluation of Curtain Wall Frame Types | - |
dc.type | Article | - |
dc.identifier.doi | 10.3130/jaabe.12.157 | - |
dc.type.rims | ART | - |
dc.identifier.bibliographicCitation | JOURNAL OF ASIAN ARCHITECTURE AND BUILDING ENGINEERING, v.12, no.1, pp.157 - 163 | - |
dc.description.journalClass | 1 | - |
dc.identifier.wosid | 000321981000021 | - |
dc.identifier.scopusid | 2-s2.0-84877912575 | - |
dc.citation.endPage | 163 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 157 | - |
dc.citation.title | JOURNAL OF ASIAN ARCHITECTURE AND BUILDING ENGINEERING | - |
dc.citation.volume | 12 | - |
dc.contributor.affiliatedAuthor | Chung, Min Hee | - |
dc.type.docType | Article | - |
dc.description.oadoiVersion | published | - |
dc.subject.keywordAuthor | curtain wall frame | - |
dc.subject.keywordAuthor | steel frame | - |
dc.subject.keywordAuthor | aluminum frame | - |
dc.subject.keywordAuthor | scagliola frame | - |
dc.subject.keywordAuthor | frame simulation(Therm6.3, Window6.3) | - |
dc.subject.keywordPlus | BUILDING ENVELOPE | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | ahci | - |
dc.description.journalRegisteredClass | scopus | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Soongsil University Library 369 Sangdo-Ro, Dongjak-Gu, Seoul, Korea (06978)02-820-0733
COPYRIGHT ⓒ SOONGSIL UNIVERSITY, ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.