Analysis on fault current limiting and recovery characteristics of a flux-lock type SFCL with an isolated transformer
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Ko, Seckcheol | - |
dc.contributor.author | Lim, Sung-Hun | - |
dc.contributor.author | Han, Tae-Hee | - |
dc.date.available | 2018-05-09T14:17:55Z | - |
dc.date.created | 2018-04-17 | - |
dc.date.issued | 2013-01 | - |
dc.identifier.issn | 0921-4534 | - |
dc.identifier.uri | http://scholarworks.bwise.kr/ssu/handle/2018.sw.ssu/11395 | - |
dc.description.abstract | The flux-lock type superconducting fault current limiter (SFCL) can quickly limit the fault current shortly after the short circuit occurs and recover the superconducting state after the fault removes. However, the superconducting element comprising the flux-lock type SFCL can be destructed when the high fault current passes through the SFCL. Therefore, the countermeasure to control the fault current and protect the superconducting element is required. In this paper, the flux-lock type SFCL with an isolated transformer, which consists of two parallel connected coils on an iron core and the isolated transformer connected in series with one of two coils, was proposed and the short-circuit experimental device to analyze the fault current limiting and the recovery characteristics of the flux-lock type SFCL with the isolated transformer were constructed. Through the short-circuit tests, the flux-lock type SFCL with the isolated transformer was confirmed to perform more effective fault current limiting and recovery operation compared to the flux-lock type SFCL without the isolated transformer from the viewpoint of the quench occurrence and the recovery time of the SFCL. (C) 2012 Elsevier B.V. All rights reserved. | - |
dc.publisher | ELSEVIER SCIENCE BV | - |
dc.relation.isPartOf | PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS | - |
dc.subject | 2 COILS | - |
dc.subject | SERIES | - |
dc.subject | CONNECTION | - |
dc.title | Analysis on fault current limiting and recovery characteristics of a flux-lock type SFCL with an isolated transformer | - |
dc.type | Article | - |
dc.identifier.doi | 10.1016/j.physc.2012.03.041 | - |
dc.type.rims | ART | - |
dc.identifier.bibliographicCitation | PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, v.484, pp.263 - 266 | - |
dc.description.journalClass | 1 | - |
dc.identifier.wosid | 000316932000064 | - |
dc.identifier.scopusid | 2-s2.0-84875648052 | - |
dc.citation.endPage | 266 | - |
dc.citation.startPage | 263 | - |
dc.citation.title | PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS | - |
dc.citation.volume | 484 | - |
dc.contributor.affiliatedAuthor | Lim, Sung-Hun | - |
dc.type.docType | Article; Proceedings Paper | - |
dc.subject.keywordAuthor | The flux-lock type superconducting fault current limiter (SFCL) | - |
dc.subject.keywordAuthor | Fault current limiting and recovery operation | - |
dc.subject.keywordPlus | 2 COILS | - |
dc.subject.keywordPlus | SERIES | - |
dc.subject.keywordPlus | CONNECTION | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Soongsil University Library 369 Sangdo-Ro, Dongjak-Gu, Seoul, Korea (06978)02-820-0733
COPYRIGHT ⓒ SOONGSIL UNIVERSITY, ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.