CNT/PDMS Composite Flexible Dry Electrodes for Long-Term ECG Monitoring

Authors
Jung, Ha-ChulMoon, Jin-HeeBaek, Dong-HyunLee, Jae-HeeChoi, Yoon-YoungHong, Joung-SookLee, Sang-Hoon
Issue Date
May-2012
Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Keywords
Biocompatible; carbon nanotube (CNT)/polydimethylsiloxane (PDMS) composite electrode; ECG electrode; long-term monitoring
Citation
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, v.59, no.5, pp.1472 - 1479
Journal Title
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING
Volume
59
Number
5
Start Page
1472
End Page
1479
URI
http://scholarworks.bwise.kr/ssu/handle/2018.sw.ssu/12437
DOI
10.1109/TBME.2012.2190288
ISSN
0018-9294
Abstract
We fabricated a carbon nanotube (CNT)/polydimethylsiloxane (PDMS) composite-based dry ECG electrode that can be readily connected to conventional ECG devices, and showed its long-term wearable monitoring capability and robustness to motion and sweat. While the dispersion of CNTs in PDMS is challenging, we optimized the process to disperse untreated CNTs within PDMS by mechanical force only. The electrical and mechanical characteristics of the CNT/PDMS electrode were tested according to the concentration of CNTs and its thickness. The performances of ECG electrodes were evaluated by using 36 types of electrodes which were fabricated with different concentrations of CNTs, and with a differing diameter and thickness. The ECG signals were obtained by using electrodes of diverse sizes to observe the effects of motion and sweat, and the proposed electrode was shown to be robust to both factors. The CNT concentration and diameter of the electrodes were critical parameters in obtaining high-quality ECG signals. The electrode was shown to be biocompatible from the cytotoxicity test. A seven-day continuous wearability test showed that the quality of the ECG signal did not degrade over time, and skin reactions such as itching or erythema were not observed. This electrode could be used for the long-term measurement of other electrical biosignals for ubiquitous health monitoring including EMG, EEG, and ERG.