High voltage ultrawide band pulse generator using Blumlein pulse forming line
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Jin, Y. S. | - |
dc.contributor.author | Lim, S. W. | - |
dc.contributor.author | Cho, C. H. | - |
dc.contributor.author | Kim, J. S. | - |
dc.contributor.author | Kim, Y. B. | - |
dc.contributor.author | Lee, S. H. | - |
dc.contributor.author | Roh, Y. | - |
dc.date.available | 2018-05-10T05:25:13Z | - |
dc.date.created | 2018-04-17 | - |
dc.date.issued | 2012-04 | - |
dc.identifier.issn | 0034-6748 | - |
dc.identifier.uri | http://scholarworks.bwise.kr/ssu/handle/2018.sw.ssu/12466 | - |
dc.description.abstract | A high voltage ultrawide band pulse generation system has been developed to radiate intense and ultrawide band electric fields for the examination of effects of the electric fields on the operation of electronic devices. As major components of the system, a helical strip/wire type of air-cored pulse transformer and a triaxial type of Blumlein pulse forming line have been designed and fabricated to amplify and shape the output pulse, respectively. For the construction of a compact system, the pulse transformer and the Blumlein line are installed in a single cylindrical container. An ultrawide band TEM horn antenna has been fabricated to radiate the Blumlein output pulses to electronic devices. A number of experimental results demonstrate that the system is capable of providing an output pulse whose voltage is greater than 300 kV, pulse duration is similar to 5 ns, and rise time is similar to 500 ps with repetition rate of 10 Hz. The peak-to-peak value of electric field intensity of a radiated pulse is also measured to be approximately 42 kV/m at a distance of 10 m away from the antenna. (C) 2012 American Institute of Physics. [http://dx.doi.org.access.yonsei.ac.kr:8080/10.1063/1.3703307] | - |
dc.publisher | AMER INST PHYSICS | - |
dc.relation.isPartOf | REVIEW OF SCIENTIFIC INSTRUMENTS | - |
dc.title | High voltage ultrawide band pulse generator using Blumlein pulse forming line | - |
dc.type | Article | - |
dc.identifier.doi | 10.1063/1.3703307 | - |
dc.type.rims | ART | - |
dc.identifier.bibliographicCitation | REVIEW OF SCIENTIFIC INSTRUMENTS, v.83, no.4 | - |
dc.description.journalClass | 1 | - |
dc.identifier.wosid | 000303415300055 | - |
dc.identifier.scopusid | 2-s2.0-84860593939 | - |
dc.citation.number | 4 | - |
dc.citation.title | REVIEW OF SCIENTIFIC INSTRUMENTS | - |
dc.citation.volume | 83 | - |
dc.contributor.affiliatedAuthor | Roh, Y. | - |
dc.type.docType | Article | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
Soongsil University Library 369 Sangdo-Ro, Dongjak-Gu, Seoul, Korea (06978)02-820-0733
COPYRIGHT ⓒ SOONGSIL UNIVERSITY, ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.