Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Analysis of Electric Substitution Effects by the Gas Consumption and Characteristics of Gas Cooling System

Full metadata record
DC Field Value Language
dc.contributor.author박래준-
dc.contributor.author송경빈-
dc.date.available2018-05-10T05:51:37Z-
dc.date.created2018-04-17-
dc.date.issued2012-05-
dc.identifier.issn1975-8359-
dc.identifier.urihttp://scholarworks.bwise.kr/ssu/handle/2018.sw.ssu/12817-
dc.description.abstractRecently, the amount of electrical heat pump(EHP), a electrical conditioning equipment, is sharply increasing due to the luxury and multi-story trend of building. Accordingly, the cooling load that occupying substantial part of summer electric consumption has increased dramatically, making difficulties in domestic supply of electricity in summer. There are some efforts to replace it with an alternative cooling equipment such as gas heat pump(GHP), a gas cooling equipment, in order to solve the problem of summer electricity supply through reducing the summer electricity peak. It is rare, however, to find studies on the actual effects of GHP on the reduction of summer electricity peak. This study,therefore, estimated the effects of the GHP on the summer electricity peak by the gas consumption and characteristics of gas cooling systems. In addition, electric substitution effects by gas cooling systems were analyzed through case studies in the summer of 2010.-
dc.language한국어-
dc.language.isoko-
dc.publisherKorean Institute of Electrical Engineers-
dc.relation.isPartOfTransactions of the Korean Institute of Electrical Engineers-
dc.subjectElectrical heat pump-
dc.subjectGas cooling systems-
dc.subjectElectric substitution effects-
dc.subjectThe gas consumption-
dc.titleAnalysis of Electric Substitution Effects by the Gas Consumption and Characteristics of Gas Cooling System-
dc.title.alternative냉방기기 사용량과 특성을 고려한 가스냉방기기의 전력대체 효과 분석-
dc.typeArticle-
dc.identifier.doi10.5370/KIEE.2012.61.5.669-
dc.type.rimsART-
dc.identifier.bibliographicCitationTransactions of the Korean Institute of Electrical Engineers, v.61, no.5, pp.669 - 675-
dc.identifier.kciidART001659635-
dc.description.journalClass1-
dc.identifier.scopusid2-s2.0-84861518086-
dc.citation.endPage675-
dc.citation.number5-
dc.citation.startPage669-
dc.citation.titleTransactions of the Korean Institute of Electrical Engineers-
dc.citation.volume61-
dc.contributor.affiliatedAuthor송경빈-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.subject.keywordAuthorElectrical heat pump-
dc.subject.keywordAuthorGas cooling systems-
dc.subject.keywordAuthorElectric substitution effects-
dc.subject.keywordAuthorThe gas consumption-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Electrical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Song, Kyung Bin photo

Song, Kyung Bin
College of Engineering (School of Electrical Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE